ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5905-00-419-3798, 5905004193798
RESISTOR,FIXED,WIRE WOUND

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 004193798
Codification Country
United States
Item Name Code
INC 00010
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-00-419-3798
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-00-419-3798


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-00-419-3798

National Stock Number (NSN) 5905-00-419-3798, or NIIN 004193798, (resistor,fixed,wire wound) was assigned December 2, 1970 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 9 manufacturer part numbers associated with this NSN. 5 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 6 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00010. [A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF SUPPORTING. OPPOSITION TO THE FLOW OF CURRENT IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFEST BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES:SUPPRESSOR,IGNITION INTERFERENCE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905004193798 does not contain precious metals.

This NSN is associated to Schedule B 8533390080: wirewound variable resistors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.030/+0.030
UNABLE TO DECODE
(AAQZ) UNABLE TO DECODE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER
(AAQF) 125.0
TERMINAL TYPE
(AARB) WIRE LEAD
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -10.0/+10.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0/+125.0
INCLOSURE METHOD
(AAQZ) ENCAPSULATED
UNABLE TO DECODE
(AAQF) UNABLE TO DECODE
UNABLE TO DECODE
(AARB) UNABLE TO DECODE
ELECTRICAL RESISTANCE
(AAPP) 48.000 KILOHMS
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 125.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER
(AAQG) 145.0
BODY DIAMETER
(ABPM) 0.141 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 0.391 INCHES MAXIMUM
INCLOSURE TYPE
(AKNA) ENCAPSULATED
POWER DISSIPATION RATING IN WATTS
(AEFB) 0.0521 FREE AIR
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.030 TO 0.030
STYLE DESIGNATOR
(STYL) AXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -10.0 TO 10.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0 TO 125.0
TERMINAL LENGTH
(ABJT) 1.000 INCHES MINIMUM
TERMINAL TYPE
(CSCF) WIRE LEAD
TEST DATA DOCUMENT
(TEST) 06481-900532 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 125.0 DEG CELSIUS

Manufacturer Part Numbers

1017000225

RNCC
5
RNVC
9
101A225

RNCC
5
RNVC
9
900532225

RNCC
3
RNVC
2
HR42225

RNCC
5
RNVC
9
K532225

RNCC
5
RNVC
9
R1652225

RNCC
5
RNVC
1
SP42W0113225

RNCC
5
RNVC
1
WW1314225

RNCC
5
RNVC
9
WWA1314225

RNCC
5
RNVC
1

Related Inventory

90101A225
Condition NE
NUT, JAM, HEX H
Readily Available


 
Top