ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-465-1764, 5925014651764
INTERRUPTER,GROUND FAULT

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 014651764
Codification Country
United States
Item Name Code
INC 32522
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-465-1764
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-465-1764


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-465-1764

National Stock Number (NSN) 5925-01-465-1764, or NIIN 014651764, (interrupter,ground fault) was assigned May 25, 1999 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 19, 2013, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32522. [AN ELECTRICAL SAFETY DEVICE DESIGNED FOR INSERTION IN A POWER DISTRIBUTION CIRCUIT TO PROVIDE PROTECTION AGAINST SERIOUS INJURY OR DEATH CAUSED BY CONTACT WITH DAMAGED OR DEFECTIVE ELECTRICAL EQUIPMENT. IT DISCONNECTS THE UNGROUNDED CONDUCTOR(S) WHEN ITS INTEGRAL CIRCUITRY SENSES AN UNDESIRABLE CURRENT FLOW TO EARTH (GROUND). IT INCLUDES A RESET FEATURE AND MAY HAVE A TEST FACILITY. IT MAY BE DESIGNED FOR INSTALLATION IN AN ELECTRICAL PANEL OR BOX, OR MAY BE A PORTABLE UNIT WITH ITS OWN ENCLOSURE. MAY INCLUDE SWITCHES, CIRCUIT BREAKERS, FUSES, AND THE LIKE; PORTABLE UNITS MAY HAVE CONNECTING CABLES. EXCLUDES OVERCURRENT PROTECTIVE DEVICES WHICH ALSO PROVIDE A GROUND FAULT SENSING AND INTERRUPTING CAPABILITY. SEE ALSO CIRCUIT BREAKER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925014651764 does not contain precious metals.

This NSN is associated to Schedule B 8538907020: automatic circuit breaker parts for headings 8535, 8536 or 8537. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

END ITEM IDENTIFICATION
(AGAV) 7022014398251
COLOR
(HUES) GRAY/GREY
CURRENT RATING
(ARAG) 20.000 AMPERES
OVERALL LENGTH
(ABHP) 2.700 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 1.590 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) HOSPITAL GRADE DUPLEX GFCI RECEPTACLE WITH LED INDICATOR LIGHT
VOLTAGE IN VOLTS AND CURRENT TYPE
(CSBH) 125.0 AC
UNABLE TO DECODE
(FEAT) UNABLE TO DECODE
UNABLE TO DECODE
(HUES) UNABLE TO DECODE
UNABLE TO DECODE
(CSBH) UNABLE TO DECODE
UNABLE TO DECODE
(ARAG) UNABLE TO DECODE
COLOR
(HUES) GRAY
UNABLE TO DECODE
(AGAV) UNABLE TO DECODE
UNABLE TO DECODE
(ABHP) UNABLE TO DECODE
UNABLE TO DECODE
(ABMK) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top