NSN 5925-00-682-0742, 5925006820742
Cancelled -> Replaced by 5925000751646

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 006820742
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-682-0742
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-682-0742


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-682-0742

National Stock Number (NSN) 5925-00-682-0742, or NIIN 006820742, (circuit breaker) was assigned January 1, 1961 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5925000751646.

There are 8 manufacturer part numbers associated with this NSN. 4 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 4 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 19, 2013, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925006820742 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) 0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT EACH POLE
BODY LENGTH
(ADAQ) 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE
(AAQL) MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH
(ADAT) 2.265 INCHES MAXIMUM
BOSS HEIGHT
(AJEC) 0.150 INCHES NOMINAL
CASE MATERIAL
(CWJK) PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ
(FREQ) 400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) MOISTURE RESISTANT AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP ALL LOCATIONS
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 250.0 AC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 41.0 AMPERES AC THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 69.0 AMPERES AC FIRST LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 69.0 AMPERES AC SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.475 INCHES NOMINAL
POLE QUANTITY
(AKPX) 3
RESET METHOD
(CPRQ) MANUAL
THREAD SERIES DESIGNATOR
(THSD) UNC
THREAD QUANTITY PER INCH
(CMLP) 32
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) MAGNETIC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 0.200 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 150.0 ALL LOCATIONS
TERMINAL TYPE AND QUANTITY
(TTQY) 6 THREADED STUD
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
CASE MATERIAL
(ADTV) PLASTIC

Manufacturer Part Numbers

13208E58382

RNCC
1
RNVC
2
1320BE58382

RNCC
5
RNVC
2
721701MG6

RNCC
5
RNVC
9
721701MGL

RNCC
5
RNVC
9
721702H66

RNCC
5
RNVC
9
721702MG6

RNCC
5
RNVC
9
APL11146322

RNCC
5
RNVC
2
C21914

RNCC
3
RNVC
9
C21914

ISC
2
RNCC
C
RNVC
1

Related Inventory

212C219-144
470BB5-10
Condition FN
UNIV.HEAD 5052-
Request


 
Top