NSN 5925-01-595-2374, 5925015952374
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 015952374
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-595-2374
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-595-2374


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-595-2374

National Stock Number (NSN) 5925-01-595-2374, or NIIN 015952374, (circuit breaker) was assigned April 25, 2011 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925015952374 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

CASE MATERIAL
(ADTV) METAL
BODY LENGTH
(ADAQ) 1.562 INCHES NOMINAL
BODY STYLE
(AAQL) SINGLE POLE TYPE
BODY WIDTH
(ADAT) 1.281 INCHES NOMINAL
BUSHING LENGTH
(ABXD) 0.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 7.5 DC SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 20.0 AMPERES DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 2 SLOT
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 1.605 INCHES NOMINAL
MOUNTING SLOT WIDTH
(ABTD) 0.130 INCHES NOMINAL
POLE QUANTITY
(AKPX) 1
RESET METHOD
(CPRQ) AUTOMATIC
SPECIAL FEATURES
(FEAT) DELAY:DC SHORT TIME DELAY
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 40.0 MINIMUM AT 100 PCT AND 0.015 MAXIMUM AT 800 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD
(CPRJ) MAGNETIC SINGLE LOCATION
TERMINAL TYPE AND QUANTITY
(TTQY) 2 QUICK DISCONNECT, MALE
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE