ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5945-00-957-4942, 5945009574942
Cancelled -> Replaced by 5945009848056

Federal Supply Classification
FSC 5945 - Relays and Solenoids
National Item Identification Number
NIIN 009574942
Codification Country
United States
Item Name Code
INC 32512
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 6 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5945-00-957-4942
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5945-00-957-4942


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5945-00-957-4942

National Stock Number (NSN) 5945-00-957-4942, or NIIN 009574942, (relay,electromagnetic) was assigned January 1, 1962 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5945009848056.

There are 4 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Sep 28, 2009. There has been one contract issued for this part number, with one award given. The US Government has only awarded those contracts to one supplier. The last contract numbers awarded were: SPM7M809M4459, SPM7M809M4459. The total value of the awarded contracts has been US$ 27,888.00.

This NSN is somewhat common among different platforms, belonging to 9 different weapons systems.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. The 24 month forecast from the US Government for this part number has high volatility, with an estimated forecasted value of US$ 9,681. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Nov 02, 2005, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.

This NSN is assigned to Item Name Code (INC) 32512. [A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES:CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5945009574942 contains an unknown precious metal.

This NSN is associated to Schedule B 8536490050: relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335314: relay and industrial control manufacturing.

This information was last updated on .


Technical Characteristics

DUTY TYPE
(APNP) CONTINUOUS
ARC QUENCHING METHOD
(APNQ) AIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 1.844 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY
(APCN) 1
CUBIC MEASURE
(CBME) 3.239 CUBIC INCHES
ENVIRONMENTAL PROTECTION
(ADZC) HERMETIC
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
FREQUENCY IN HERTZ
(AJSS) 400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 3.0 AMPERES AC AND 3.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 800.0 MILLIAMPERES AC AND 800.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS
(CWAB) 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 1.5 AMPERES AC AND 1.5 AMPERES DC MOTOR LOAD
OVERALL HEIGHT
(ABKW) 2.156 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 2.187 INCHES MAXIMUM
OVERALL WIDTH
(ABMK) 0.687 INCHES MAXIMUM
MOUNTING FACILITY PATTERN
(CQYJ) IN-LINE SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT
(CRNG) 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP
(CSXF) 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNED
(AKSL) GENERAL
SPECIFICATION/STANDARD DATA
(ZZZK) 96906-MS25321 GOVERNMENT STANDARD
WINDING QUANTITY
(AKDX) 1
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY
(TTQY) 8 PIN ALL FUNCTIONS
TEST DATA DOCUMENT
(TEST) 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY
(CRXH) 0.025 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY
(CRXH) 0.05 SECONDS MAXIMUM FIXED RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER
(AEBV) 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD
III CUBIC MEASURE
(CBME) 3.239 CUBIC INCHES
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 1.5 AMPERES AC MOTOR LOAD AND 1.5 AMPERES DC MOTOR LOAD
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) UNABLE TO DECODE
CASE MATERIAL
(ADTV) METAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD

Manufacturer Part Numbers


Related Inventory

MS25321-A2

Condition NE
Relay
Readily Available


 
Top