ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5905-00-855-6129, 5905008556129
Cancelled -> Replaced by 5905006369911

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 008556129
Codification Country
United States
Item Name Code
INC 00010
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 2 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-00-855-6129
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-00-855-6129


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-00-855-6129

National Stock Number (NSN) 5905-00-855-6129, or NIIN 008556129, (resistor,fixed,wire wound) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 3 stock numbers: 5905001001340, 5905006369911, 5905005498924.

There are no manufacturer part numbers associated to this NSN. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 00010. [A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF SUPPORTING. OPPOSITION TO THE FLOW OF CURRENT IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFEST BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES:SUPPRESSOR,IGNITION INTERFERENCE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905008556129 contains an unknown precious metal.

This NSN is associated to Schedule B 8533390080: wirewound variable resistors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

III ELECTRICAL RESISTANCE
(AAPP) 5.100 OHMS
UNABLE TO DECODE
(AAPQ) UNABLE TO DECODE
UNABLE TO DECODE
(AAQF) UNABLE TO DECODE
UNABLE TO DECODE
(AARB) UNABLE TO DECODE
UNABLE TO DECODE
(ABJT) UNABLE TO DECODE
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -5.000/+5.000
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0/+350.0
UNABLE TO DECODE
(AAQZ) UNABLE TO DECODE
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -400.0/+400.0
UNABLE TO DECODE
(AAPP) UNABLE TO DECODE
UNABLE TO DECODE
(AAQH) UNABLE TO DECODE
INCLOSURE METHOD
(AAQZ) ENCAPSULATED
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER
(AAQF) 25.0
UNABLE TO DECODE
(ABPM) UNABLE TO DECODE
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
UNABLE TO DECODE
(CBME) UNABLE TO DECODE
TERMINAL TYPE
(AARB) FERRULE
UNABLE TO DECODE
(AEFB) UNABLE TO DECODE
UNABLE TO DECODE
(STYL) UNABLE TO DECODE
ELECTRICAL RESISTANCE
(AAPP) 5.100 OHMS
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 DEG CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER
(AAQG) 350.0
BODY DIAMETER
(ABPM) 1.406 INCHES NOMINAL
BODY LENGTH
(ADAQ) 6.500 INCHES NOMINAL
CUBIC MEASURE
(CBME) 10.092 CUBIC INCHES
INCLOSURE TYPE
(AKNA) ENCAPSULATED
POWER DISSIPATION RATING IN WATTS
(AEFB) 125.000 FREE AIR
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -5.000 TO 5.000
TEST DATA DOCUMENT
(TEST) 81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA
(ZZZK) 81349-MIL-R-26/1 GOVERNMENT SPECIFICATION
STYLE DESIGNATOR
(STYL) AXIAL TERMINAL EACH END
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0 TO 350.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -400.0 TO 400.0
TERMINAL LENGTH
(ABJT) 0.562 INCHES NOMINAL
TERMINAL TYPE
(CSCF) FERRULE
UNABLE TO DECODE
(AAQG) UNABLE TO DECODE
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
CUBIC MEASURE (NON-CORE)
(CBME) 10.092 CUBIC INCHES
UNABLE TO DECODE
(AAPE) UNABLE TO DECODE
UNABLE TO DECODE
(ZZZK) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory

RW12V5R1
5905008556129
Condition NS
RESISTOR
Readily Available


 
Top