NSN 4820-01-495-1585, 4820014951585
VALVE,BALL

Federal Supply Classification
FSC 4820 - Valves, Nonpowered
National Item Identification Number
NIIN 014951585
Codification Country
United States
Item Name Code
INC 20962
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 4820-01-495-1585
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 4820-01-495-1585


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 4820-01-495-1585

National Stock Number (NSN) 4820-01-495-1585, or NIIN 014951585, (valve,ball) was assigned March 7, 2002 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Nov 09, 2017. There have been 2 contracts issued for this part number, with 2 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 2 different suppliers. The last contract numbers awarded were: SPE7MC18P0874, SPE7MC17VB055. The total value of the awarded contracts has been US$ 907.74.

This NSN is somewhat common among different platforms, belonging to 6 different weapons systems.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jan 02, 2013, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 20962. [A MULTI-PORTED, NONLUBRICATED VALVE DESIGNED TO PROVIDE STRAIGHT THROUGH FLOW OR ABILITY TO DIRECT A NUMBER OF FLOWS OR PRESSURE THROUGH A SINGLE VALVE. THE FLOW IS CONTROLLED BY THE ROTATION OF A PORTED BALL WITHIN A SUITABLE PORTED SEAT(S). THE BALL IS USUALLY ENGAGED BY A STEM. IT IS NORMALLY OPERATED IN AN OPEN OR CLOSED POSITION. EXCLUDES:VALVE, CHECK.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 4820014951585 does not contain precious metals.

This information was last updated on .


Technical Characteristics

CONNECTION TYPE
(AWLS) THREADED INTERNAL PIPE ALL ENDS
FURNISHED ITEMS AND QUANTITY
(TMQY) 1 HANDLE
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) B124-C37700 ASSN STD 1ST MATERIAL RESPONSE OR B16-C36000 ASSN STD 2ND MATERIAL RESPONSE FLOW CONTROL DEVICE
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) B124-C37700 ASSN STD 1ST MATERIAL RESPONSE OR B584-C857 ASSN STD 2ND MATERIAL RESPONSE BODY
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) B16-C36000 ASSN STD SINGLE MATERIAL RESPONSE STEM
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) POLYTETRAFLUOROETHYLENE MFR REF SINGLE MATERIAL RESPONSE PACKING
MATERIAL
(MATT) COPPER ALLOY 360 STEM
MATERIAL
(MATT) COPPER ALLOY 377 OR COPPER ALLOY 360 FLOW CONTROL DEVICE
MATERIAL
(MATT) COPPER ALLOY 377 OR COPPER ALLOY 857 BODY
MATERIAL
(MATT) PLASTIC POLYTETRAFLUOROETHYLENE PACKING
MAXIMUM OPERATING PRESSURE
(CQGM) 125.0 POUNDS PER SQUARE INCH 2ND RESPONSE
MAXIMUM OPERATING PRESSURE
(CQGM) 600.0 POUNDS PER SQUARE INCH 1ST RESPONSE
MEDIA FOR WHICH DESIGNED
(MEDA) STEAM 2ND RESPONSE
MEDIA FOR WHICH DESIGNED
(MEDA) WATER-OIL-GAS 1ST RESPONSE
NOMINAL THREAD SIZE
(CQJX) 1.000 INCHES ALL ENDS
SPECIAL FEATURES
(FEAT) VALVE IAW FED SPEC WWV-35B; THREADED ENDS IAW ANSI B1.20.1; BALL IS HARD CHROMIUM PLATED
STYLE DESIGNATOR
(STYL) STRAIGHT THRU
VALVE OPERATION METHOD
(AQLR) MANUAL
MATERIAL
(MATT) COPPER ALLOY 377 FLOW CONTROL DEVICE OR COPPER ALLOY 360 FLOW CONTROL DEVICE
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) TEFLON MFR REF SINGLE MATERIAL RESPONSE PACKING
STYLE DESIGNATOR
(STYL) A1 STRAIGHT THRU
STYLE DESIGNATOR
(STYL) ERR-090
MATERIAL
(MATT) COPPER ALLOY 377 BODY OR COPPER ALLOY 857 BODY

Manufacturer Part Numbers


Related Inventory

25-16
2540013948155
Condition NS
BLADE
Readily Available
12948155
4730-01-368-7541
Request
M8504948-15-5F
WMM85049/48-15-5
Condition NE

Request
M85049
WM85049/48-15-5F
Condition NE

Request


 
Top