ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5360-01-664-0408, 5360016640408
SPRING,HELICAL,EXTENSION

Federal Supply Classification
FSC 5360 - Coil, Flat, Leaf, and Wire Springs
National Item Identification Number
NIIN 016640408
Codification Country
United States
Item Name Code
INC 04227
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5360-01-664-0408
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5360-01-664-0408


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5360-01-664-0408

National Stock Number (NSN) 5360-01-664-0408, or NIIN 016640408, (spring,helical,extension) was assigned June 2, 2017 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 03, 2017, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 04227. [AN OPEN- OR CLOSE-COILED SPRING WOUND IN VARIOUS FORMS AND FROM DIFFERENT SHAPES AND TYPES OF MATERIALS AND FINISHED AT THE ENDS, DESIGNED IN SUCH A WAY AS TO PROVIDE RESISTANCE TO PULLING FORCES. THE CLOSE-COILED SPRINGS MAY INCORPORATE THE SPECIAL FEATURE OF INITIAL TENSION CREATED BETWEEN THE COILS WHEN WOUND, REQUIRING AN INITIAL LOAD TO BE APPLIED TO SEPARATE THEM. EXCLUDES:SPRING,REINFORCING HOSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5360016640408 does not contain precious metals.

This information was last updated on .


Technical Characteristics

COIL HELIX DIRECTION
(AXLH) RIGHT-HAND
COIL QUANTITY
(APCN) 30.5
DESIGN TYPE
(APGF) CLOSED
END STYLE
(ABQK) MACHINE CUT-OFF BOTH ENDS
III END ITEM IDENTIFICATION
(AGAV) 5410-01-592-9464
INSIDE DIAMETER
(AARX) 0.207 INCHES NOMINAL
MATERIAL
(MATT) STEEL CORROSION RESISTING OVERALL
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) SPRING,EXTENSION
SPRING DEFLECTION RATE
(AXLP) 13.04 POUNDS PER INCH NOMINAL
SPRING FREE LENGTH
(AGEK) 10.0 INCHES NOMINAL
SPRING LENGTH UNDER LOAD
(CSZP) 18.68 INCHES MAXIMUM
SPRING FREE OUTSIDE DIAMETER
(AXLQ) 2.00 INCHES NOMINAL
STYLE DESIGNATOR
(STYL) CYLINDRICAL
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION
(STDC) ASTM A967 ASSN STD SINGLE TREATMENT RESPONSE OVERALL
SURFACE TREATMENT
(SFTT) PASSIVATE OVERALL
UNABLE TO DECODE
(APCN) UNABLE TO DECODE
UNABLE TO DECODE
(AARX) UNABLE TO DECODE
UNABLE TO DECODE
(AXLQ) UNABLE TO DECODE
SURFACE TREATMENT
(SFTT) UNABLE TO DECODE
MATERIAL
(MATT) UNABLE TO DECODE
UNABLE TO DECODE
(AGEK) UNABLE TO DECODE
UNABLE TO DECODE
(AXLP) UNABLE TO DECODE
STYLE DESIGNATOR
(STYL) ERR-090
UNABLE TO DECODE
(ABQK) UNABLE TO DECODE
UNABLE TO DECODE
(APGF) UNABLE TO DECODE
UNABLE TO DECODE
(CSZP) UNABLE TO DECODE
UNABLE TO DECODE
(AXLH) UNABLE TO DECODE
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION
(STDC) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top