Item Name Code
INC 00309
Criticality
(Y) This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-00-081-8147
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-00-081-8147


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-00-081-8147

National Stock Number (NSN) 5905-00-081-8147, or NIIN 000818147, (resistor,thermal) was assigned January 1, 1961 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 6685012192886.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 3 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jan 01, 2013, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00309. [A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES:TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.]. This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905000818147 does not contain precious metals.

This NSN is associated to Schedule B 8533400080: variable resistors, including potentiometers, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -73.3 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP
(CRQJ) -10.0/+10.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -15.0/+15.0 ALL RESISTANCE-TEMPERATURE POINTS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 316.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
MAXIMUM OPERATING TEMP
(AEHZ) 150.0 DEG CELSIUS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 93.3 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -17.8 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
III END ITEM IDENTIFICATION
(AGAV) SUBMARINE INTERIOR COMMUNICATION SYSTEM; MOORED TRAINING SHIP; SUBMARINE COMMUNICATIONS AND ANTENNA SYSTEMS; OLIVER PERRY CLASS FFG
III ZERO POWER RESISTANCE
(CQWD) 109.400 KILOHMS
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 CELSIUS
BODY OUTSIDE DIAMETER
(ADAR) 0.300 INCHES NOMINAL
BODY WIDTH
(ADAT) 0.060 INCHES NOMINAL
CRITICALITY CODE JUSTIFICATION
(CRTL) FEAT
END ITEM IDENTIFICATION
(AGAV) SUBMARINE INTERIOR COMMUNICATION SYSTEM; MOORED TRAINING SHIP; SUBMARINE COMMUNICATIONS AND ANTENNA SYSTEMS; OLIVER PERRY CLASS FFG
INCLOSURE TYPE
(AKNA) ENCAPSULATED
MAXIMUM OPERATING TEMP
(AEHZ) 150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING
(AEHX) 1.00 WATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS
(AEJB) 8.0
REFERENCE TEMP IN DEG CELSIUS
(CTGT) 25.0
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS
SPECIAL FEATURES
(FEAT) WEAPON SYSTEM ESSENTIAL
STYLE DESIGNATOR
(STYL) DISK
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 107.5 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 194.6 OHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 308.8 OHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 464.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 71.6 OHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP
(CRQJ) -10.0 TO 10.0
ZERO POWER RESISTANCE
(CQWD) 109.400 KILOHMS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -17.8 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -73.3 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 204.4 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 316.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 93.3 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER
(AEBT) 0.020 INCHES NOMINAL
TERMINAL LENGTH
(ABJT) 2.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY
(TTQY) 2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS
(AEJA) 60.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 204.4 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 DEG CELSIUS