NSN 5905-01-542-2091, 5905015422091
RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 015422091
Codification Country
United States
Item Name Code
INC 37405
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-01-542-2091
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-01-542-2091


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-01-542-2091

National Stock Number (NSN) 5905-01-542-2091, or NIIN 015422091, (resistor,variable,nonwire wound,nonprecision) was assigned July 26, 2006 in the Federal Logistics Information System (FLIS). NIIN 015422091 was cancelled on August 29, 2018, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 37405. [A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, AND THE LIKE, SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES:RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905015422091 does not contain precious metals.

This information was last updated on .


Technical Characteristics

MOUNTING HOLE DIAMETER
(ABTB) 0.062 INCHES MINIMUM AND 0.082 INCHES MAXIMUM
UNABLE TO DECODE
(ABWV) UNABLE TO DECODE
BODY LENGTH
(ADAQ) 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
UNABLE TO DECODE
(ADAT) UNABLE TO DECODE AND UNABLE TO DECODE
SHAFT DIAMETER
(ABWV) 0.078 INCHES NOMINAL
SHAFT LENGTH
(ABXF) 0.080 INCHES MAXIMUM
SHAFT STYLE
(AEDX) ROUND, SLOTTED
UNABLE TO DECODE
(AEFL) UNABLE TO DECODE
UNABLE TO DECODE
(ADAU) UNABLE TO DECODE AND UNABLE TO DECODE
MAXIMUM RUNNING TORQUE
(AEFL) 5.00 INCH-OUNCES
MOUNTING METHOD
(AXGY) UNTHREADED HOLE
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS
(CRFJ) -100.0/+100.0 SINGLE SECTION
TEST DATA DOCUMENT
(TEST) 81349-MIL-PRF-22097 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
UNABLE TO DECODE
(AGTP) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY
(AKPV) 2
UNABLE TO DECODE
(AKPV) UNABLE TO DECODE
UNABLE TO DECODE
(AXGY) UNABLE TO DECODE
STANDARD TAPER CURVE PER SECTION
(CSDL) A SINGLE SECTION
TERMINAL TYPE AND QUANTITY
(TTQY) 3 WIRE LEAD
TERMINAL LOCATION
(APXH) REAR END
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS
(CRFJ) -100.0 TO 100.0 SINGLE SECTION
BODY STYLE
(AAQL) RECTANGULAR W/MOUNTING HOLES
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(CQCC) UNABLE TO DECODE
UNABLE TO DECODE
(CRFJ) UNABLE TO DECODE
UNABLE TO DECODE
(ABXF) UNABLE TO DECODE
BODY WIDTH
(ADAT) 0.145 INCHES MINIMUM AND 0.160 INCHES MAXIMUM
UNABLE TO DECODE
(AEDX) UNABLE TO DECODE
UNABLE TO DECODE
(AEFK) UNABLE TO DECODE
ELECTRICAL RESISTANCE PER SECTION
(CQCC) 200000.0 OHMS SINGLE SECTION
UNABLE TO DECODE
(CRSS) UNABLE TO DECODE
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER
(CSDH) 85.0 SINGLE SECTION
UNABLE TO DECODE
(AAPN) UNABLE TO DECODE
UNABLE TO DECODE
(APXH) UNABLE TO DECODE
UNABLE TO DECODE
(CQGN) UNABLE TO DECODE
RESISTANCE TOLERANCE PER SECTION IN PERCENT
(CRSS) -10.0/+10.0 SINGLE SECTION
SECTION QUANTITY
(AAPN) 1
UNABLE TO DECODE
(AAQL) UNABLE TO DECODE
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
MAXIMUM STARTING TORQUE
(AEFK) 5.00 INCH-OUNCES
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS
(AGTP) 0.419 INCHES NOMINAL
UNABLE TO DECODE
(CSDL) UNABLE TO DECODE
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
UNABLE TO DECODE
(ABTB) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(AEFD) UNABLE TO DECODE
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER
(CQGN) 150.0 SINGLE SECTION
ACTUATOR TYPE
(AEFD) SINGLE SHAFT
POWER DISSIPATION RATING PER SECTION IN WATTS
(CRGD) 0.5 FREE AIR SINGLE SECTION
RESISTANCE TOLERANCE PER SECTION IN PERCENT
(CRSS) -10.0 TO 10.0 SINGLE SECTION
UNABLE TO DECODE
(CRGD) UNABLE TO DECODE
UNABLE TO DECODE
(CSDH) UNABLE TO DECODE
SPECIFICATION/STANDARD DATA
(ZZZK) 81349-MIL-PRF-22097/4 GOVERNMENT SPECIFICATION
UNABLE TO DECODE
(ZZZK) UNABLE TO DECODE