NSN 5910-01-224-0274, 5910012240274
CAPACITOR,FIXED,CERAMIC DIELECTR

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 012240274
Codification Country
United States
Item Name Code
INC 00007
Criticality
(Y) This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-01-224-0274
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-01-224-0274


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-01-224-0274

National Stock Number (NSN) 5910-01-224-0274, or NIIN 012240274, (capacitor,fixed,ceramic dielectr) was assigned January 11, 1986 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00007. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A CERAMIC DIELECTRIC. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910012240274 does not contain precious metals.

This information was last updated on .


Technical Characteristics

BODY STYLE
(AAQL) W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION
(CQBQ) 33000.000 PICOFARADS SINGLE SECTION
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT
(CWPM) 2.5000
NONDERATED OPERATING TEMP
(CQJJ) -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) NO COMMON OR GROUNDED ELECTRODE(S)
CASE MATERIAL
(CWJK) PLASTIC
TERMINAL SURFACE TREATMENT
(CWSG) SOLDER
TERMINAL DIAMETER
(AEBT) 0.024 INCHES MINIMUM AND 0.029 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
BODY LENGTH
(ADAQ) 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP
(CQBF) 10000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 100.0 DC SINGLE SECTION
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
CRITICALITY CODE JUSTIFICATION
(CRTL) FEAT
UNABLE TO DECODE
(ABHP) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(ABMK) UNABLE TO DECODE AND UNABLE TO DECODE
BODY WIDTH
(ADAT) 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
INSULATION RESISTANCE AT REFERENCE TEMP
(CWPK) 100000.0 MEGOHMS
SPECIAL FEATURES
(FEAT) BURN-IN TEST
TERMINAL LENGTH
(ABJT) 1.250 INCHES MINIMUM
BODY HEIGHT
(ADAU) 0.080 INCHES MINIMUM AND 0.100 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
UNABLE TO DECODE
(ABKW) UNABLE TO DECODE AND UNABLE TO DECODE
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE
(CQFB) -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
TOLERANCE RANGE PER SECTION
(CRTP) -10.00 TO 10.00 PERCENT SINGLE SECTION

Manufacturer Part Numbers


Related Inventory



 