ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-00-066-6887, 5925000666887
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 000666887
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-066-6887
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-066-6887


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-066-6887

National Stock Number (NSN) 5925-00-066-6887, or NIIN 000666887, (circuit breaker) was assigned January 1, 1961 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 1991, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925000666887 contains silver.

This information was last updated on .


Technical Characteristics

ARC QUENCHING METHOD
(APNQ) DEION
FEATURES PROVIDED
(CBBL) ADJUSTABLE TRIP RELEASE
UNABLE TO DECODE
(CPRH) UNABLE TO DECODE
RESET METHOD
(CPRQ) MANUAL
CASE MATERIAL
(CWJK) PLASTIC
OVERALL LENGTH
(ABHP) 10.180 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 5.500 INCHES NOMINAL
POLE QUANTITY
(AKPX) 2
UNABLE TO DECODE
(CBBL) UNABLE TO DECODE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
UNABLE TO DECODE
(CPRW) UNABLE TO DECODE
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
CASE MATERIAL
(ADTV) PLASTIC
UNABLE TO DECODE
(CPRJ) UNABLE TO DECODE
NOMINAL THREAD SIZE
(CQJX) 0.312 INCHES
UNABLE TO DECODE
(CQJX) UNABLE TO DECODE
TERMINAL TYPE AND QUANTITY
(TTQY) 4 COMPRESSION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 AMPERES AC ALL LOCATIONS AND 10000.0 AMPERES DC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC AND 250.0 DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 15000.0 AC AND 15000.0 DC ALL LOCATIONS
UNABLE TO DECODE
(CPRQ) UNABLE TO DECODE
UNABLE TO DECODE
(CPRT) UNABLE TO DECODE
III ARC QUENCHING METHOD
(APNQ) DEION
UNABLE TO DECODE
(APNQ) UNABLE TO DECODE
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 4 UNTHREADED HOLE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
UNABLE TO DECODE
(CRCF) UNABLE TO DECODE
UNABLE TO DECODE
(CWJK) UNABLE TO DECODE
UNABLE TO DECODE
(FEAT) UNABLE TO DECODE
UNABLE TO DECODE
(ABHP) UNABLE TO DECODE
UNABLE TO DECODE
(ABMK) UNABLE TO DECODE
UNABLE TO DECODE
(AXHR) UNABLE TO DECODE
SPECIAL FEATURES
(FEAT) MTG HOLES ON 7.250 IN. BY 2.750 IN. MTG CENTERS
UNABLE TO DECODE
(FREQ) UNABLE TO DECODE
UNABLE TO DECODE
(PRMT) UNABLE TO DECODE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 AMPERES AC AND 10000.0 AMPERES DC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 117.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) DUSTPROOF
UNABLE TO DECODE
(AKPX) UNABLE TO DECODE
OVERALL HEIGHT
(ABKW) 8.250 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 15000.0 AC ALL LOCATIONS AND 15000.0 DC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
ACTUATOR FUNCTION
(CPRW) TRIP W/SEPARATE RESET
PRECIOUS MATERIAL
(PRMT) SILVER
UNABLE TO DECODE
(ABKW) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) THERMAL-MAGNETIC ALL LOCATIONS
UNABLE TO DECODE
(CPRN) UNABLE TO DECODE
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
TRIP RELEASE CHARACTERISTIC
(CPRL) INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
UNABLE TO DECODE
(CPRR) UNABLE TO DECODE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 300.000 MINIMUM AT 150 PCT AND 1400.000 MAXIMUM AT 150 PCT AND 100.000 MINIMUM AT 200 PCT AND 400.000 MAXIMUM AT 200 PCT AND 30.000 MINIMUM AT 300 PCT AND 100.000 MAXIMUM AT 300 PCT AND 16.000 MINIMUM AT 400 PCT AND 55.000 MAXIMUM AT 400 PCT AND 10.000 MINIMUM AT 500 PCT AND 35.000 MAXIMUM AT 500 PCT AND 0.040 MINIMUM AT 1000 PCT AND 10.000 MAXIMUM AT 1000 PCT ALL LOCATIONS
UNABLE TO DECODE
(CQXF) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS