CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 002659487
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-265-9487
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-265-9487


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-265-9487

National Stock Number (NSN) 5925-00-265-9487, or NIIN 002659487, (circuit breaker) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925002659487 contains an unknown precious metal.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 4 THREADED HOLE
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS
CASE MATERIAL
(ADTV) METAL
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 75.0 DEG FAHRENHEIT NOMINAL ALL LOCATIONS
TERMINAL TYPE AND QUANTITY
(TTQY) 4 SCREW
ACTUATOR FUNCTION
(CPRW) TRIP-RESETTRIP-RESET
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS60.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE1 TOGGLE
OVERALL LENGTH
(ABHP) 9.000 INCHES NOMINAL9.000 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 4.875 INCHES NOMINAL4.875 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 50.0 AMPERES AC ALL LOCATIONS50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 5000.0 AC ALL LOCATIONS5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 4 THREADED HOLE(S)4 THREADED HOLE(S)
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 120.0 AC FIRST LOCATION120.0 AC FIRST LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 240.0 AC SECOND LOCATION240.0 AC SECOND LOCATION
OVERALL HEIGHT
(ABKW) 3.500 INCHES NOMINAL3.500 INCHES NOMINAL
POLE QUANTITY
(AKPX) 22
RESET METHOD
(CPRQ) MANUALMANUAL
TERMINAL TYPE AND QUANTITY
(TTQY) 4 SCREW4 SCREW
THREAD SERIES DESIGNATOR
(THSD) UNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC)
THREAD QUANTITY PER INCH
(CMLP) 3232
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 252.000 NOMINAL AT 125 PCT AND 252.000 NOMINAL AT 125 PCT AND 20.000 MINIMUM AT 200 PCT AND 20.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT AND 6.000 MINIMUM AT 300 PCT AND 6.000 MINIMUM AT 300 PCT AND 10.000 MAXIMUM AT 300 PCT ALL LOCATIONS10.000 MAXIMUM AT 300 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 75.0 FAHRENHEIT NOMINAL ALL LOCATIONS75.0 FAHRENHEIT NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) THERMAL ALL LOCATIONSTHERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 115.0 ALL LOCATIONS115.0 ALL LOCATIONS
THREAD QUANTITY PER INCH
(CMLP) 32
TRIP RELEASE CHARACTERISTIC
(CPRL) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 115.0 ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) UNABLE TO DECODE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) UNABLE TO DECODE
THREAD SERIES DESIGNATOR
(THSD) UNC
POLE QUANTITY
(AKPX) 2
TRIP RELEASE METHOD
(CPRJ) UNABLE TO DECODE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) UNABLE TO DECODE
RESET METHOD
(CPRQ) MANUAL
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) UNABLE TO DECODE
CIRCUIT PROTECTION TYPE
(CPRH) UNABLE TO DECODE
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) UNABLE TO DECODE