NSN 5925-00-313-6049, 5925003136049
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 003136049
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-313-6049
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-313-6049


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-313-6049

National Stock Number (NSN) 5925-00-313-6049, or NIIN 003136049, (circuit breaker) was assigned November 2, 1973 in the Federal Logistics Information System (FLIS). NIIN 003136049 was cancelled on December 15, 2017, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925003136049 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(ABXD) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC AND MAGNETIC-HYDRAULIC ALL LOCATIONS
UNABLE TO DECODE
(CPRL) UNABLE TO DECODE
ULTIMATE TRIP TIME PER POLE IN SECONDS
(CPRP) 0.010 MINIMUM ALL LOCATIONS AND 0.040 MAXIMUM ALL LOCATIONS
SWITCH TERMINAL TYPE
(CRTK) TAB, SOLDER LUG
POLE QUANTITY
(AKPX) 2
UNABLE TO DECODE
(THSD) UNABLE TO DECODE
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
UNABLE TO DECODE
(CQXF) UNABLE TO DECODE
RESET METHOD
(CPRQ) MANUAL
UNABLE TO DECODE
(CPRQ) UNABLE TO DECODE
UNABLE TO DECODE
(CQSM) UNABLE TO DECODE
TERMINAL TYPE AND QUANTITY
(TTQY) 4 WIRE HOOK
BODY LENGTH
(ADAQ) 1.500 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 1.780 INCHES MAXIMUM
ULTIMATE TRIP TIME PER POLE IN SECONDS
(CPRP) 0.010 MINIMUM AND 0.040 MAXIMUM ALL LOCATIONS
UNABLE TO DECODE
(CPRW) UNABLE TO DECODE
UNABLE TO DECODE
(CPRZ) UNABLE TO DECODE
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
BUSHING LENGTH
(ABXD) 0.380 INCHES MAXIMUM
UNABLE TO DECODE
(AEBP) UNABLE TO DECODE
UNABLE TO DECODE
(AEBQ) UNABLE TO DECODE
SWITCH CONTACT ARRANGEMENT
(AEGJ) SINGLE POLE, DOUBLE THROW
UNABLE TO DECODE
(AJWX) UNABLE TO DECODE
UNABLE TO DECODE
(AKPX) UNABLE TO DECODE
THREAD QUANTITY PER INCH
(CMLP) 32
UNABLE TO DECODE
(CMLP) UNABLE TO DECODE
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) BETWEEN POLE ONE AND TWO
UNABLE TO DECODE
(CPRX) UNABLE TO DECODE
NOMINAL THREAD SIZE
(CQJX) 0.375 INCHES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) HERMETICALLY SEALED
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
UNABLE TO DECODE
(AXHR) UNABLE TO DECODE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 MILLIAMPERES DC SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 500.0 DC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS
UNABLE TO DECODE
(CRTK) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.875 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 750.0 MILLIAMPERES DC FIRST LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 50.0 DC SECOND LOCATION
TRIP RELEASE CHARACTERISTIC
(CPRL) INSTANTANEOUS ALL LOCATIONS
UNABLE TO DECODE
(AEGJ) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC ALL LOCATIONS AND MAGNETIC-HYDRAULIC ALL LOCATIONS
UNABLE TO DECODE
(CPRR) UNABLE TO DECODE
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP ALL LOCATIONS
UNABLE TO DECODE
(CPSM) UNABLE TO DECODE
SWITCH LOCATION AND POSITION DESIGNATION
(CQSM) INTERNAL AT POLE ONE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 0.625 INCHES NOMINAL
UNABLE TO DECODE
(CPRH) UNABLE TO DECODE
UNABLE TO DECODE
(CPRN) UNABLE TO DECODE
UNABLE TO DECODE
(CPRT) UNABLE TO DECODE
AUXILIARY SWITCH FUNCTION AND QUANTITY
(CPRZ) 1 CONTROL
UNABLE TO DECODE
(CQJX) UNABLE TO DECODE
BODY WIDTH
(ADAT) 1.250 INCHES MAXIMUM
UNABLE TO DECODE
(ADAT) UNABLE TO DECODE
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 1 THREADED BUSHING W/PANEL SEAL
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) THD BUSHING W/PANEL SEAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 500.0 DC AND 500.0 DC ALL LOCATIONS
UNABLE TO DECODE
(AAQL) UNABLE TO DECODE
UNABLE TO DECODE
(CPLM) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 115.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE AND TWO LINKED
THREAD SERIES DESIGNATOR
(THSD) UNEF
CASE MATERIAL
(ADTV) METAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 50.0 DC FIRST LOCATION
UNABLE TO DECODE
(CPRF) UNABLE TO DECODE
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
UNABLE TO DECODE
(CPRY) UNABLE TO DECODE