CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 004093605
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-409-3605
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-409-3605


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-409-3605

National Stock Number (NSN) 5925-00-409-3605, or NIIN 004093605, (circuit breaker) was assigned July 15, 1970 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925004093605 contains an unknown precious metal.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

CASE MATERIAL
(ADTV) PLASTIC
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY SINGLE LOCATION
CASE MATERIAL
(CWJK) PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 10.0 AMPERES DC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 50.0 DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 2000.0 DC SINGLE LOCATION
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT SINGLE LOCATION
UNPACKAGED UNIT WEIGHT
(PKWT) 4.250 OUNCES
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP SINGLE LOCATION
UNABLE TO DECODE
(PKWT) UNABLE TO DECODE
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE ONE
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
BODY LENGTH
(ADAQ) 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE
(AAQL) SINGLE POLE TYPE
BODY WIDTH
(ADAT) 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BOSS HEIGHT
(AJEC) 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE
(CPRH) UNABLE TO DECODE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) UNABLE TO DECODE
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
MATERIAL
(MATT) PLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) UNABLE TO DECODE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) UNABLE TO DECODE
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) UNABLE TO DECODE
POLE QUANTITY
(AKPX) 1
RESET METHOD
(CPRQ) MANUAL
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY
(TTQY) 2 THREADED STUD
THREAD QUANTITY PER INCH
(CMLP) 32
THREAD SERIES DESIGNATOR
(THSD) UNC
TRIP RELEASE CHARACTERISTIC
(CPRL) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) UNABLE TO DECODE
UNPACKAGED UNIT WEIGHT
(CTJS) 4.250 OUNCES NOMINAL
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 2.500 MINIMUM AT 200 PCT AND 6.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC SINGLE LOCATION

Manufacturer Part Numbers


Related Inventory

10-07613
6431502-1
Condition NE
True Blue Power
Readily Available
M2464315-02UN

Condition NE
LSDSGU-4
Readily Available
12414315-021 REV XC
5310-01-434-3778
Washer/Nut
Readily Available
12414315-020
5310013726337
Condition NS
NUT
Readily Available
12414315-021
5310014343778
Condition NS
NUT
Readily Available
460359
4820-01-243-1502
Condition NE
DIAPHRAGM
Readily Available
7671C12414315-020
5310-01-372-6337
Condition NE
NUT, PLAIN HEX
Readily Available
FE200373-05
3940 -01-443-150
SLING,MULTIPLE
Readily Available
43-1502
Condition FN
Desc: BOLT; MOQ
Readily Available
63543-150-2