ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-00-580-0869, 5925005800869
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 005800869
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-580-0869
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-580-0869


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-580-0869

National Stock Number (NSN) 5925-00-580-0869, or NIIN 005800869, (circuit breaker) was assigned January 29, 1968 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925005800869 does not contain precious metals.

This information was last updated on .


Technical Characteristics

STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1000.0 AC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 115.0 SINGLE LOCATION
FREQUENCY IN HERTZ
(FREQ) 400.0 SINGLE LOCATION
THREAD PITCH DIAMETERS
(AAJE) +0.3503/+0.3537 INCHES
POLE QUANTITY
(AKPX) 1
THREAD QUANTITY PER INCH
(CMLP) 32
TRIP RELEASE METHOD
(CPRJ) MAGNETIC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE ONE
THREAD PITCH DIAMETERS
(AAJE) +0.3503 TO 0.3537 INCHES
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 230.0 AC SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 0.070 MINIMUM AT 200 PCT AND 0.700 MAXIMUM AT 200 PCT SINGLE LOCATION
UNPACKAGED UNIT WEIGHT
(PKWT) 1.800 OUNCES
BODY WIDTH
(ADAT) 0.625 INCHES MAXIMUM
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
UNABLE TO DECODE
(PKWT) UNABLE TO DECODE
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY SINGLE LOCATION
CASE MATERIAL
(ADTV) METAL
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 1 THREADED BUSHING W/PANEL SEAL
BODY STYLE
(AAQL) SINGLE POLE TYPE
BUSHING LENGTH
(ABXD) 0.380 INCHES MAXIMUM
SPECIAL HANDLING FEATURE
(BBRJ) MAGNETIC
RESET METHOD
(CPRQ) MANUAL
NOMINAL THREAD SIZE
(CQJX) 0.375 INCHES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF
BODY LENGTH
(ADAQ) 1.562 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 1.605 INCHES MAXIMUM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 1.75 AMPERES AC SINGLE LOCATION
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT SINGLE LOCATION
TERMINAL TYPE AND QUANTITY
(TTQY) 2 WIRE HOOK
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
UNPACKAGED UNIT WEIGHT
(CTJS) 1.800 OUNCES NOMINAL
THREAD SERIES DESIGNATOR
(THSD) UNEF
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP SINGLE LOCATION

Manufacturer Part Numbers