CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 009784961
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-978-4961
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-978-4961


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-978-4961

National Stock Number (NSN) 5925-00-978-4961, or NIIN 009784961, (circuit breaker) was assigned October 12, 1966 in the Federal Logistics Information System (FLIS). NIIN 009784961 was cancelled on August 29, 2018, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925009784961 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
POLE QUANTITY
(AKPX) 3
OPERATING VOLTAG
(CPRF) 250.0 AC ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.650 INCHES MINIMUM AND 2.800 INCHES MAXIMUM
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
SWITCH TERMINAL TYPE
(CRTK) TAB, SOLDER LUG
BODY WIDTH
(ADAT) 2.230 INCHES MINIMUM AND 2.270 INCHES MAXIMUM
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 3 TOGGLE
ACTUATOR POSITION DESIGNATION
(CPRX) AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY
(CPRZ) 1 ALARM
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 ALL LOCATIONS
SWITCH CONTACT ARRANGEMENT
(AEGJ) SINGLE POLE, DOUBLE THROW
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
THREAD SERIES DESIGNATOR
(THSD) UNC
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 THREADED HOLE
RESET METHOD
(CPRQ) MANUAL
BODY LENGTH
(ADAQ) 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 250.0 AC ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE, TWO, AND THREE LINKED
SWITCH CURRENT RATING AND TYPE IN AMPS
(CSSX) 5.0 AC AND 1.0 DC
FREQUENCY IN HERTZ
(FREQ) 400.0 ALL LOCATIONS
BOSS HEIGHT
(AJEC) 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 2.5 AMPERES AC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 3.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TEST DATA DOCUMENT
(TEST) 05869-711570 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TERMINAL TYPE AND QUANTITY
(TTQY) 6 THREADED STUD
BODY STYLE
(AAQL) MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL
(ADTV) PLASTIC
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) MAGNETIC ALL LOCATIONS
UNPACKAGED UNIT WEIGHT
(PKWT) 0.875 POUNDS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1000.0 AC ALL LOCATIONS
SWITCH VOLTAGE RATING AND TYPE IN VOLTS
(CSWP) 115.0 AC AND 50.0 DC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
SPECIAL HANDLING FEATURE
(BBRJ) MAGNETIC
THREAD QUANTITY PER INCH
(CMLP) 32
SWITCH LOCATION AND POSITION DESIGNATION
(CQSM) INTERNAL AT POLE THREE