CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 010693440
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-069-3440
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-069-3440


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-069-3440

National Stock Number (NSN) 5925-01-069-3440, or NIIN 010693440, (circuit breaker) was assigned December 14, 1978 in the Federal Logistics Information System (FLIS). NIIN 010693440 was cancelled on December 15, 2017, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925010693440 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
SWITCH VOLTAGE RATING AND TYPE IN VOLTS
(CSWP) 250.0 AC
FREQUENCY IN HERTZ
(FREQ) 400.0 ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 0.020 MINIMUM AT 500 PCT ALL LOCATIONS AND 0.070 MAXIMUM AT 500 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
RESET METHOD
(CPRQ) MANUAL
AUXILIARY SWITCH FUNCTION AND QUANTITY
(CPRZ) 1 ALARM
SWITCH CURRENT RATING AND TYPE IN AMPS
(CSSX) 2.5 AC
TERMINAL TYPE AND QUANTITY
(TTQY) 6 THREADED STUD
CASE MATERIAL
(ADTV) METAL
POLE QUANTITY
(AKPX) 3
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 250.0 AC ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS
(CPRP) 0.600 MINIMUM ALL LOCATIONS AND 2.000 MAXIMUM ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1000.0 AC ALL LOCATIONS
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
THREAD QUANTITY PER INCH
(CMLP) 32
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
SWITCH LOCATION AND POSITION DESIGNATION
(CQSM) EXTERNAL AT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) FUNGUS RESISTANT AND MOISTURE RESISTANT
BODY STYLE
(AAQL) MULTIPOLE-MULTIPLE ACTUATOR TYPE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
OPERATING VOLTAG
(CPRF) 250.0 AC ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE, TWO, AND THREE LINKED
UNPACKAGED UNIT WEIGHT
(PKWT) 12.750 OUNCES
THREAD SERIES DESIGNATOR
(THSD) UNC
BODY LENGTH
(ADAQ) 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 3 TOGGLE
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.539 INCHES MINIMUM AND 2.683 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 THREADED HOLE
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP ALL LOCATIONS
BODY WIDTH
(ADAT) 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
SWITCH TERMINAL TYPE
(CRTK) TURRET
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
SWITCH CONTACT ARRANGEMENT
(AEGJ) SINGLE POLE, DOUBLE THROW
BOSS HEIGHT
(AJEC) 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 6.0 AMPERES AC ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 150.0 ALL LOCATIONS