ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-096-5890, 5925010965890
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 010965890
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-096-5890
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-096-5890


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-096-5890

National Stock Number (NSN) 5925-01-096-5890, or NIIN 010965890, (circuit breaker) was assigned June 25, 1980 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 19, 2013, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925010965890 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE TWO
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
BODY LENGTH
(ADAQ) 1.500 INCHES MAXIMUM
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH
(ADAT) 1.875 INCHES MAXIMUM
BUSHING LENGTH
(ABXD) 0.250 INCHES MINIMUM AND 0.312 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
FREQUENCY IN HERTZ
(FREQ) 430.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) HERMETICALLY SEALED AND MOISTURE RESISTANT AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SERIES TRIP ALL LOCATIONS
NOMINAL THREAD SIZE
(CQJX) 0.375 INCHES
NONTURN DEVICE DIAMETER
(AEFS) 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
NONTURN DEVICE RADIUS
(AEFP) 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 120.0 AC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 15.0 AMPERES AC THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 25.0 AMPERES AC FIRST LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 25.0 AMPERES AC SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 1.780 INCHES MAXIMUM
POLE QUANTITY
(AKPX) 3
RESET METHOD
(CPRQ) MANUAL
THREAD PITCH DIAMETERS
(AAJE) +0.3503 TO 0.3537 INCHES
THREAD SERIES DESIGNATOR
(THSD) UNEF
THREAD QUANTITY PER INCH
(CMLP) 32
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 0.200 MINIMUM AT 200 PCT AND 6.000 MAXIMUM AT 200 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 ALL LOCATIONS
UNPACKAGED UNIT WEIGHT
(CTJS) 11.100 OUNCES NOMINAL
SPECIAL HANDLING FEATURE
(BBRJ) MAGNETIC
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY
(TTQY) 6 WIRE HOOK
UNPACKAGED UNIT WEIGHT
(PKWT) 11.100 OUNCES
NONTURN DEVICE LOCATION
(AEFN) AT 3 OCLOCK AND AT 9 OCLOCK
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
CASE MATERIAL
(ADTV) METAL
UNABLE TO DECODE
(AEFN) UNABLE TO DECODE AND UNABLE TO DECODE
THREAD PITCH DIAMETERS
(AAJE) +0.3503/+0.3537 INCHES
UNABLE TO DECODE
(PKWT) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 