ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-159-6599, 5925011596599
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 011596599
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-159-6599
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-159-6599


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-159-6599

National Stock Number (NSN) 5925-01-159-6599, or NIIN 011596599, (circuit breaker) was assigned August 11, 1983 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925011596599 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

TRIP RELEASE METHOD
(CPRJ) UNABLE TO DECODE
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) UNABLE TO DECODE
UNPACKAGED UNIT WEIGHT
(PKWT) 12.312 POUNDS
CASE MATERIAL
(ADTV) PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 8 THREADED HOLE
CASE MATERIAL
(CWJK) PLASTIC
THREAD SERIES DESIGNATOR
(THSD) UNC
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
CIRCUIT PROTECTION TYPE
(CPRH) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) UNABLE TO DECODE
UNABLE TO DECODE
(PKWT) UNABLE TO DECODE
TRIP RELEASE CHARACTERISTIC
(CPRL) UNABLE TO DECODE
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT EACH POLE
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
AUXILIARY SWITCH FUNCTION AND QUANTITY
(CPRZ) ALARM 1
BODY LENGTH
(ADAQ) INCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTH
(ADAT) INCHES MINIMUM 2.960 AND INCHES MAXIMUM 3.040
BOSS HEIGHT
(AJEC) INCHES MINIMUM 0.130 AND INCHES MAXIMUM 0.150
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) INCHES MINIMUM 1.928 AND INCHES MAXIMUM 1.948
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) INCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
CIRCUIT PROTECTION TYPE
(CPRH) ALL LOCATIONS OVERCURRENT
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) INCHES MINIMUM 2.052 AND INCHES MAXIMUM 2.072
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) INCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE, TWO, THREE, AND FOUR LINKED
FEATURES PROVIDED
(CBBL) HIGH INRUSH PROTECTION
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
FREQUENCY IN HERTZ
(FREQ) 400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) FOURTH LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) FIRST LOCATION SERIES TRIP W/AUXILIARY LOAD TERMINAL
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) SECOND LOCATION SERIES TRIP
INTERNAL TRIP RELEASE CONFIGURATION
(CPSM) THIRD LOCATION SERIES TRIP
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) TOGGLE 4
MATERIAL
(MATT) CASE PLASTIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) FIRST LOCATION AC 1000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) SECOND LOCATION AC 1000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) FOURTH LOCATION DC 1000.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) THIRD LOCATION AC 1000.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) FIRST LOCATION AMPERES AC 20.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) SECOND LOCATION AMPERES AC 20.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) THIRD LOCATION AMPERES AC 20.0
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) THREADED HOLE(S) 8
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) INCHES MINIMUM 2.403 AND INCHES MAXIMUM 2.533
NOMINAL THREAD SIZE
(CQJX) INCHES 0.138
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) FIRST LOCATION AC 240.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) FOURTH LOCATION DC 24.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) SECOND LOCATION AC 240.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) THIRD LOCATION AC 240.0
POLE QUANTITY
(AKPX) 4
RESET METHOD
(CPRQ) MANUAL
SPECIAL FEATURES
(FEAT) HIGH INRUSH POLE ONE ONLY AND POLE FOUR IS A REMOTE VOLTAGE TRIP APPLICATION
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
SWITCH CONTACT ARRANGEMENT
(AEGJ) SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS
(CSSX) AC 10.0 AND DC 4.0
SWITCH LOCATION AND POSITION DESIGNATION
(CQSM) INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE
(CRTK) TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS
(CSWP) AC 250.0 AND DC 30.0
TERMINAL TYPE AND QUANTITY
(TTQY) THREADED STUD 9
TEST DATA DOCUMENT
(TEST) STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). 04655-29-512113
THREAD QUANTITY PER INCH
(CMLP) 32
THREAD SERIES DESIGNATOR
(THSD) UNIFIED NATIONAL COARSE (UNC)
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) THIRD LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
TRIP RELEASE CHARACTERISTIC
(CPRL) ALL LOCATIONS TIME DELAY
TRIP RELEASE METHOD
(CPRJ) ALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) FIRST LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) FOURTH LOCATION MINIMUM AT 200 PCT 0.150 AND MAXIMUM AT 200 PCT 1.500
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) SECOND LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 130.0
UNPACKAGED UNIT WEIGHT
(CTJS) POUNDS NOMINAL 12.312
SPECIAL HANDLING FEATURE
(BBRJ) MAGNETIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) UNABLE TO DECODE
MATERIAL
(MATT) UNABLE TO DECODE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) UNABLE TO DECODE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 