NSN 5925-01-236-1016, 5925012361016
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 012361016
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-236-1016
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-236-1016


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-236-1016

National Stock Number (NSN) 5925-01-236-1016, or NIIN 012361016, (circuit breaker) was assigned July 11, 1986 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jul 20, 1999, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925012361016 contains silver.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 9.875 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) 3.000 INCHES NOMINAL
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE TWO
ARC QUENCHING METHOD
(APNQ) MAGNETIC BLOWOUT
BODY LENGTH
(ADAQ) 11.000 INCHES MAXIMUM
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH
(ADAT) 9.000 INCHES MAXIMUM
BOSS HEIGHT
(AJEC) 0.063 INCHES NOMINAL
CASE MATERIAL
(CWJK) PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 9.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 3.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) GENERAL PURPOSE
NOMINAL THREAD SIZE
(CQJX) 0.250 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 500.0 AC AND 250.0 DC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 250.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 20000.0 AC AND 15000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 9.218 INCHES MAXIMUM
POLE QUANTITY
(AKPX) 3
PRECIOUS MATERIAL AND LOCATION
(PMLC) CONTACT SURFACES SILVER
PRECIOUS MATERIAL
(PRMT) SILVER
RESET METHOD
(CPRQ) MANUAL
SPECIAL FEATURES
(FEAT) MOUNTING HARDWARE INCLUDED
TEST DATA DOCUMENT
(TEST) 81349-MIL-C-17361 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THREAD SERIES DESIGNATOR
(THSD) UNC
THREAD QUANTITY PER INCH
(CMLP) 20
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 ALL LOCATIONS
SPECIFICATION/STANDARD DATA
(ZZZK) 81349-MIL-C-17361 GOVERNMENT SPECIFICATION
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY
(TTQY) 6 THREADED STUD
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 500.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS
CASE MATERIAL
(ADTV) PLASTIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 20000.0 AC ALL LOCATIONS AND 15000.0 DC ALL LOCATIONS
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE