ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-250-5070, 5925012505070
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 012505070
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-250-5070
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-250-5070


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-250-5070

National Stock Number (NSN) 5925-01-250-5070, or NIIN 012505070, (circuit breaker) was assigned March 3, 1987 in the Federal Logistics Information System (FLIS). NIIN 012505070 was cancelled on December 15, 2017, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925012505070 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

ACTUATOR FUNCTION
(CPRW) TRIP-RESET
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 25.000 MINIMUM AT 125 PCT ALL LOCATIONS AND 450.000 MAXIMUM AT 125 PCT ALL LOCATIONS AND 3.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.200 MINIMUM AT 400 PCT ALL LOCATIONS AND 4.000 MAXIMUM AT 400 PCT ALL LOCATIONS AND 0.013 MINIMUM AT 600 PCT ALL LOCATIONS AND 0.100 MINIMUM AT 600 PCT ALL LOCATIONS AND 0.009 MINIMUM AT 800 PCT ALL LOCATIONS AND 0.040 MAXIMUM AT 800 PCT ALL LOCATIONS
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) MAGNETIC-HYDRAULIC ALL LOCATIONS
RESET METHOD
(CPRQ) MANUAL
FREQUENCY IN HERTZ
(FREQ) 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
CASE MATERIAL
(ADTV) PLASTIC
POLE QUANTITY
(AKPX) 2
OPERATING VOLTAG
(CPRF) 250.0 AC AND
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 2.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 250.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS
SPECIAL FEATURES
(FEAT) ILLUMINATED HANDLE
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS

Manufacturer Part Numbers


Related Inventory



 
Top