ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-259-5464, 5925012595464
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 012595464
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-259-5464
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-259-5464


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-259-5464

National Stock Number (NSN) 5925-01-259-5464, or NIIN 012595464, (circuit breaker) was assigned July 18, 1987 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925012595464 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

ACTUATOR FUNCTION
(CPRW) TRIP-RESET
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS
(CPSF) +500.0 TO 1000.0 AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE ONE
ARC QUENCHING METHOD
(APNQ) AIRAIR
AUXILIARY SWITCH FUNCTION AND QUANTITY
(CPRZ) 3 ALARM
BODY HEIGHT
(ADAU) 3.812 INCHES NOMINAL3.812 INCHES NOMINAL
BODY LENGTH
(ADAQ) 10.125 INCHES NOMINAL10.125 INCHES NOMINAL
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH
(ADAT) 5.500 INCHES NOMINAL5.500 INCHES NOMINAL
BOSS HEIGHT
(AJEC) 0.500 INCHES NOMINAL0.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 8.876 INCHES NOMINAL8.876 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 1.719 INCHES NOMINAL1.719 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH
(AEHA) 4.125 INCHES NOMINAL4.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 2.844 INCHES NOMINAL2.844 INCHES NOMINAL
FEATURES PROVIDED
(CBBL) ADJUSTABLE TRIP RELEASEADJUSTABLE TRIP RELEASE
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGEDMODERATELY RUGGED
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 20.000 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 TERMINAL AND 6 TERMINAL AND 4 UNTHREADED HOLE(S)4 UNTHREADED HOLE(S)
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 240.0 AC ALL LOCATIONS
POLE QUANTITY
(AKPX) 33
RESET METHOD
(CPRQ) MANUAL
STORAGE TYPE
(BBRG) GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
SWITCH CONTACT ARRANGEMENT
(AEGJ) SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS
(CSSX) 100.0 AC
SWITCH LOCATION AND POSITION DESIGNATION
(CQSM) INTERNAL AT EACH POLE
SWITCH TERMINAL TYPE
(CRTK) SCREW
SWITCH VOLTAGE RATING AND TYPE IN VOLTS
(CSWP) 120.0 AC
TERMINAL TYPE AND QUANTITY
(TTQY) 6 QUICK DISCONNECT, FEMALE
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 50.0 CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER
(AEBV) 0.125 INCHES NOMINAL0.125 INCHES NOMINAL
POLE QUANTITY
(AKPX) 3
TRIP RELEASE CHARACTERISTIC
(CPRL) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) UNABLE TO DECODE
CASE MATERIAL
(ADTV) METAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) UNABLE TO DECODE
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 TERMINAL AND 4 UNTHREADED HOLE
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
CIRCUIT PROTECTION TYPE
(CPRH) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) UNABLE TO DECODE
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS
(CPSF) +500.0/+1000.0 AC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) UNABLE TO DECODE
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS
(CPSF) UNABLE TO DECODE
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) UNABLE TO DECODE
ARC QUENCHING METHOD
(APNQ) AIR
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top