ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-422-4555, 5925014224555
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 014224555
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-422-4555
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-422-4555


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-422-4555

National Stock Number (NSN) 5925-01-422-4555, or NIIN 014224555, (circuit breaker) was assigned December 1, 1995 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 3 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925014224555 does not contain precious metals.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) UNABLE TO DECODE
BODY LENGTH
(ADAQ) 2.000 INCHES NOMINAL
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH
(ADAT) 1.515 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.530 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ
(FREQ) 50.0 OR 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 250.0 MILLIAMPERES AC SECOND LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 4.0 AMPERES AC FIRST LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.232 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 250.0 AC ALL LOCATIONS
POLE QUANTITY
(AKPX) 2
TRIP RELEASE METHOD
(CPRJ) MAGNETIC ALL LOCATIONS
CIRCUIT PROTECTION TYPE
(CPRH) UNABLE TO DECODE
TRIP RELEASE METHOD
(CPRJ) UNABLE TO DECODE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS

Manufacturer Part Numbers


Related Inventory

P1145-25KGBL
P1145-1C008
Condition NE
Picric Acid, Cr
Readily Available
G6159632
HBL15FCAPGN
Condition NE
Single Pole Con
Readily Available
2XB47
HBLFCAPGN
Condition NE
Protective Cap:
Readily Available
2XB62
HBLMCAPGN
Condition NE
Protective Cap:
Readily Available
20TR12
HBL15FCAPGN
Condition NE
Single Pole Con
Readily Available
20TR07
HBL15MCAPGN
Condition NE
Single Pole Con
Readily Available
APGN66-2380-1
5925010053700
Condition NS
CIRCUIT BREAKER
Readily Available
APGN-662-22005-1
5925012816503
Condition NS
CIRCUIT BREAKER
Readily Available
APGN-66-1-62-153
5925012412698
Condition NS
CIRCUIT BREAKER
Readily Available
APGN-66-1REC3-66-752
5925011713637
Condition NS
CIRCUIT BREAKER
Readily Available
APGN66-1REC3-66-752
5925011713637
Condition NS
CIRCUIT BREAKER
Readily Available
APGN6-1-52F-203
5925014374804
Condition NS
CIRCUIT BREAKER
Readily Available
APGN111-6296-2
5925010748588
Condition NS
CIRCUIT BREAKER
Readily Available
15905PTFESPIRALWRAPG
WM15905-GREEN
Condition NE

Request


 
Top