ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5925-01-481-3184, 5925014813184
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 014813184
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-01-481-3184
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-01-481-3184


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-01-481-3184

National Stock Number (NSN) 5925-01-481-3184, or NIIN 014813184, (circuit breaker) was assigned December 28, 2000 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925014813184 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

BODY LENGTH
(ADAQ) 8.000 INCHES NOMINAL
POLE QUANTITY
(AKPX) 3
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 125.0 ALL LOCATIONS
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) GENERAL PURPOSE
SPECIAL FEATURES
(FEAT) MONITORS CIRCUIT BREAKER STATUS AND PROVIDES A REMOTE SIGNAL INDICATING TE CIRCUIT BREAKER CONTACTS ARE OPEN OR CLOSED
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 2.540 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 3.660 INCHES NOMINAL
FRAGILITY FACTOR
(AFJN) MODERATELY RUGGED
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC AND 250.0 DC ALL LOCATIONS
TRIP RELEASE METHOD
(CPRJ) THERMAL-MAGNETIC ALL LOCATIONS
RESET METHOD
(CPRQ) MANUAL
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT
(CPRY) ONE, TWO, AND THREE LINKED
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 40.000 MINIMUM AT 200 PCT AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS
BODY STYLE
(AAQL) MULTIPOLE-MULTIPLE ACTUATOR TYPE
END ITEM IDENTIFICATION
(AGAV) DECK MACHINE
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 3.510 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1250.0 AC AND 2500.0 DC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 250.0 AMPERES AC AND 250.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 1250.0 AC ALL LOCATIONS AND 2500.0 DC ALL LOCATIONS
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
CASE MATERIAL
(ADTV) PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 250.0 AMPERES AC ALL LOCATIONS AND 250.0 AMPERES DC ALL LOCATIONS
TERMINAL TYPE AND QUANTITY
(TTQY) 6 COMPRESSION
BODY WIDTH
(ADAT) 8.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 TERMINAL
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE TWO
CASE MATERIAL
(CWJK) PLASTIC
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 7.130 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE

Manufacturer Part Numbers


Related Inventory

MS51507-3
Elbow, 90 deg B
Readily Available
MS51507-32
Elbow, 90 deg B
Readily Available


 
Top