ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5930-00-103-6992, 5930001036992
SWITCH,PRESSURE

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 001036992
Codification Country
United States
Item Name Code
INC 00206
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-00-103-6992
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-00-103-6992


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-00-103-6992

National Stock Number (NSN) 5930-00-103-6992, or NIIN 001036992, (switch,pressure) was assigned June 19, 1968 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jul 02, 2005, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00206. [A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES:BAROSWITCH; SWITCH,PRESSURE-THERMOSTATIC; AND SWITCH,SENSITIVE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930001036992 contains an unknown precious metal.

This NSN is associated to Schedule B 8536509065: switches, for a voltage not exceeding 1000 volts, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335931: current-carrying wiring device manufacturing.

This information was last updated on .


Technical Characteristics

BODY LENGTH
(ADAQ) 1.770 INCHES NOMINAL
CONTACT ACTION STIMULUS
(CQGB) DECREASE
CONTACT ADJUSTABILITY
(CTYC) ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING
(CTHF) 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING
(CTHF) 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
CONTACT LOAD CURRENT RATING
(CTHF) 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT STIMULUS RATING
(CTYX) 13.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 125.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 240.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 28.0 DC AT SEA LEVEL THIRD VOLTAGE
FREQUENCY IN HERTZ
(FREQ) 60.0 SECOND VOLTAGE
FREQUENCY IN HERTZ
(FREQ) 60.0 FIRST VOLTAGE
INSIDE DIAMETER
(AARX) 0.375 INCHES NOMINAL SINGLE CONNECTION
NOMINAL THREAD SIZE
(CQJX) 0.375 INCHES SINGLE PRESSURE CONNECTION
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING TEMP RATING
(AWTN) -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM
OVERALL DIAMETER
(ADAV) 1.420 INCHES MAXIMUM
OVERALL LENGTH
(ABHP) 2.900 INCHES MAXIMUM
MEDIA FOR WHICH DESIGNED
(MEDA) GAS
MOUNTING METHOD
(AXGY) LINE
PRESSURE CONNECTOR TYPE
(CTZL) PLAIN, THREADED INTERNAL SINGLE CONNECTION
PRESSURE SWITCH TYPE
(AJZC) ABSOLUTE
PROOF PRESSURE
(CQJB) 25.00 POUNDS PER SQUARE INCH ABSOLUTE
THREAD CLASS
(AAJD) 3B SINGLE PRESSURE CONNECTION
THREAD SERIES DESIGNATOR
(THSD) UNF SINGLE PRESSURE CONNECTION
STYLE DESIGNATOR
(STYL) CYLINDRICAL
TERMINAL TYPE
(CSCF) TAB, SOLDER LUG
III STYLE DESIGNATOR
(STYL) CYLINDRICAL

Manufacturer Part Numbers


Related Inventory



 
Top