ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5930-00-626-4100, 5930006264100
SWITCH,THERMOSTATIC

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 006264100
Codification Country
United States
Item Name Code
INC 00451
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: We have 1 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-00-626-4100
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-00-626-4100


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-00-626-4100

National Stock Number (NSN) 5930-00-626-4100, or NIIN 006264100, (switch,thermostatic) was assigned March 5, 1975 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jul 02, 2005, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00451. [A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES:CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930006264100 contains an unknown precious metal.

This NSN is associated to Schedule B 9032100000: thermostats. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334512: automatic environmental control manufacturing for residential, commercial, and appliance use.

This information was last updated on .


Technical Characteristics

BODY LENGTH
(ADAQ) 0.734 INCHES MINIMUM AND 0.766 INCHES MAXIMUM
BODY WIDTH
(ADAT) 0.315 INCHES MINIMUM AND 0.321 INCHES MAXIMUM
CONTACT ACTION STIMULUS
(CQGB) INCREASE
CONTACT ADJUSTABILITY
(CTYC) DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING
(CTHF) 1.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING
(CTHF) 1.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT STIMULUS RATING
(CTYX) 110.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 116.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 105.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 111.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 5.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 30.0 DC AT SEA LEVEL SECOND VOLTAGE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS
(AEJN) 0.455 INCHES MINIMUM AND 0.465 INCHES MAXIMUM
FEATURES PROVIDED
(CBBL) HERMETICALLY SEALED CASE
FREQUENCY IN HERTZ
(FREQ) 60.0 FIRST VOLTAGE
OVERALL HEIGHT
(ABKW) 1.312 INCHES MAXIMUM
OVERALL LENGTH
(ABHP) 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
OVERALL WIDTH
(ABMK) 0.328 INCHES MINIMUM AND 0.360 INCHES MAXIMUM
MEDIA FOR WHICH DESIGNED
(MEDA) GAS OR LIQUID
MOUNTING FACILITY PATTERN
(CQYJ) TWO POSITION IN-LINE
MOUNTING METHOD
(AXGY) BRACKET AND UNTHREADED HOLE
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
STYLE DESIGNATOR
(STYL) RECTANGULAR W/BRACKET
TEMP SENSING ELEMENT TYPE
(AKBY) INTERNAL SENSOR
TERMINAL TYPE
(CSCF) TAB, SOLDER LUG
UNTHREADED MOUNTING HOLE DIAMETER
(AEBV) 0.123 INCHES MINIMUM AND 0.133 INCHES MAXIMUM
III OVERALL LENGTH
(ABHP) 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
III STYLE DESIGNATOR
(STYL) RECTANGULAR W/BRACKET

Manufacturer Part Numbers


Related Inventory



 
Top