ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5930-01-127-8159, 5930011278159
SWITCH,LIQUID LEVEL

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 011278159
Codification Country
United States
Item Name Code
INC 37187
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-01-127-8159
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-01-127-8159


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-01-127-8159

National Stock Number (NSN) 5930-01-127-8159, or NIIN 011278159, (switch,liquid level) was assigned March 9, 1982 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Nov 02, 2005, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 37187. [A SWITCH WHICH IS ACTUATED BY A FLOAT OR SENSING DEVICE(S) TO CONTROL LIQUID LEVEL AND/OR ACTUATE VISUAL OR AUDIBLE WARNING SYSTEMS. IT MAY INCLUDE A RELAY CONTROLLED BY THE SWITCH ELEMENT. EXCLUDES:TRANSMITTER,LIQUID QUANTITY.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930011278159 does not contain precious metals.

This NSN is associated to Schedule B 8413919520: parts, nesoi, of pumps for liquids. The Schedule B End Use is listed as industrial engines. NAICS classification category 333911: pump and pumping equipment manufacturing.

This information was last updated on .


Technical Characteristics

MOUNTING POSITION
(BBJX) VERTICALVERTICAL
AC VOLTAGE RATING
(ACYN) UNABLE TO DECODE
DC VOLTAGE RATING
(ACYR) UNABLE TO DECODE
VOLTAGE RATING AT MAXIMUM RATED CURRENT
(APGY) 50.0 VOLTS50.0 VOLTS
OPERATING TEMP RATING
(AWTN) 0.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
PHASE
(FAAZ) SINGLE
ELECTRICAL CONNECTION TYPE
(AGBD) CABLECABLECABLE
FLOAT QUANTITY
(AWAE) 11
RELAY
(BJKG) NOT INCLUDEDNOT INCLUDED
DC VOLTAGE RATING
(ACYR) 50.0 VOLTS MAXIMUM
FREQUENCY RATING
(ACZB) UNABLE TO DECODE
FLOAT EFFECTIVE TRAVEL
(BJKN) ANY ACCEPTABLE
ELECTRICAL CONNECTION TYPE
(AGBD) CABLE
AC VOLTAGE RATING
(ACYN) 120.0 VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
AC VOLTAGE RATING
(ACYN) 240.0 VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
AC VOLTAGE RATING
(ACYN) 50.0 VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
ACTUATION METHOD
(AFLW) BUOYANCY
CONTACT ARRANGEMENT
(BJKD) SPST,NORMALLY CLOSED
CURRENT RATING AT MAXIMUM RATED VOLTAGE
(APGW) 0.06 AMPERES RESISTIVE LOAD AND 0.04 AMPERES RESISTIVE LOAD
DC VOLTAGE RATING
(ACYR) 120.0 VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
DC VOLTAGE RATING
(ACYR) 240.0 VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
DC VOLTAGE RATING
(ACYR) 50.0 VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
FLOAT QUANTITY
(AWAE) 1
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL 3RD ALTERNATE OPERATING POWER RQMT
INTERNAL BATTERY ACCOMMODATION
(ALSF) NOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT
OVERALL DIAMETER
(ADAV) 2.000 INCHES NOMINAL
MAXIMUM CURRENT RATING
(BJKC) 0.3 AMPERES RESISTIVE LOAD
MOUNTING DIMENSIONS
(BJKP) MTD BY ONE 2.000 IN. DIA NPT PLUG
MOUNTING METHOD
(AXGY) THREAD
MOUNTING POSITION
(BBJX) VERTICAL
OPERATING TEMP RATING
(AWTN) 0.0 FAHRENHEIT MINIMUM AND 300.0 FAHRENHEIT MAXIMUM
PHASE
(FAAZ) SINGLE 1ST ALTERNATE OPERATING POWER RQMT
PHASE
(FAAZ) SINGLE 2ND ALTERNATE OPERATING POWER RQMT
PHASE
(FAAZ) SINGLE 3RD ALTERNATE OPERATING POWER RQMT
POWER CABLE LENGTH
(ABJP) 24.000 INCHES NOMINAL
RELAY
(BJKG) NOT INCLUDED
TANK INSERTION LENGTH
(BJKQ) 17.000 INCHES NOMINAL
VOLTAGE RATING AT MAXIMUM RATED CURRENT
(APGY) 50.0 VOLTS
AC VOLTAGE RATING
(ACYN) 50.0 VOLTS MAXIMUM
ACTUATION METHOD
(AFLW) BUOYANCYBUOYANCYBUOYANCY
INTERNAL BATTERY ACCOMMODATION
(ALSF) NOT INCLUDEDNOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMTNOT INCLUDED
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL
INTERNAL BATTERY ACCOMMODATION
(ALSF) NOT INCLUDED
MOUNTING METHOD
(AXGY) THREADTHREAD
PHASE
(FAAZ) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory

275A5320-2
Condition FN
BRACKET 5739
Readily Available
A5320C

Condition NE
Alpha 5320C is
Readily Available
A53204C

Condition NE
Alpha 5320/4C i
Readily Available
532014
SA532014
Condition NE
Sanitaire OEM #
Readily Available
532013
SA532013
Condition NE
Sanitaire OEM #
Readily Available
34D574
DWA5320
Condition NE
Chisel Bit: 1 i
Readily Available
2NUU2
PA5320
Condition NE
Automotive Air
Readily Available
53201
SA53201
Condition NE
Sanitaire OEM #
Readily Available
A53206-035
5365013040675
Condition NS
SHIM
Readily Available
365A53202300
Condition FN
Desc: HOSE; MOQ
Readily Available
365A53202301
Condition FN
Desc: HOSE; MOQ
Readily Available


 