ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5930-01-153-9663, 5930011539663
SWITCH,PRESSURE

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 011539663
Codification Country
United States
Item Name Code
INC 00206
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-01-153-9663
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-01-153-9663


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-01-153-9663

National Stock Number (NSN) 5930-01-153-9663, or NIIN 011539663, (switch,pressure) was assigned May 18, 1983 in the Federal Logistics Information System (FLIS). NIIN 011539663 was cancelled on December 15, 2017, with a cancelled status of "Item is Cancelled - Inactive." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. 3 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 29, 2020, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 00206. [A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES:BAROSWITCH; SWITCH,PRESSURE-THERMOSTATIC; AND SWITCH,SENSITIVE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930011539663 does not contain precious metals.

This information was last updated on .


Technical Characteristics

OVERALL HEIGHT
(ABKW) 6.563 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 2.656 INCHES NOMINAL
TERMINAL TYPE
(CSCF) TAB W/SCREW
BODY HEIGHT
(ADAU) 3.440 INCHES NOMINAL
NOMINAL THREAD SIZE
(CQJX) 0.250 INCHES SINGLE PRESSURE CONNECTION
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 150.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 220.0 AC AT SEA LEVEL SECOND VOLTAGE
THREAD QUANTITY PER INCH
(CMLP) 18 SINGLE PRESSURE CONNECTION
CONTACT ADJUSTMENT TYPE
(CTYS) INTERNAL ACTUATION POINT SCREW
END ITEM IDENTIFICATION
(AGAV) USED IN THE MAIN ENGINE CONTROL PANEL ABOARD 180 FT. CLASS COAST GUARD VESSELS
FREQUENCY IN HERTZ
(FREQ) 60.0 FIRST VOLTAGE
MOUNTING METHOD
(AXGY) BASE
STYLE DESIGNATOR
(STYL) RECTANGULAR
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
CONTACT LOAD CURRENT RATING
(CTHF) 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
OVERALL LENGTH
(ABHP) 3.469 INCHES NOMINAL
CONTACT ACTION STIMULUS
(CQGB) INCREASE
MEDIA FOR WHICH DESIGNED
(MEDA) LIQUID
THREAD SERIES DESIGNATOR
(THSD) NPT SINGLE PRESSURE CONNECTION
PRESSURE SWITCH TYPE
(AJZC) GAGE
PROOF PRESSURE
(CQJB) 240.00 POUNDS PER SQUARE INCH
CONTACT LOAD CURRENT RATING
(CTHF) 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT ADJUSTABILITY
(CTYC) ACTUATION POINT ADJUSTABLE
III STYLE DESIGNATOR
(STYL) RECTANGULAR
CONTACT ADJUSTMENT RANGE
(CTYM) +1.00/+75.00 ACTUATION POINT POUNDS PER SQUARE INCH

Manufacturer Part Numbers


Related Inventory



 
Top