NSN 5930-01-686-3868, 5930016863868
SWITCH,PRESSURE

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 016863868
Codification Country
United States
Item Name Code
INC 00206
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-01-686-3868
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-01-686-3868


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-01-686-3868

National Stock Number (NSN) 5930-01-686-3868, or NIIN 016863868, (switch,pressure) was assigned February 12, 2020 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Feb 13, 2020, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 00206. [A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES:BAROSWITCH; SWITCH,PRESSURE-THERMOSTATIC; AND SWITCH,SENSITIVE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930016863868 does not contain precious metals.

This NSN is associated to Schedule B 8536509065: switches, for a voltage not exceeding 1000 volts, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335931: current-carrying wiring device manufacturing.

This information was last updated on .


Technical Characteristics

FREQUENCY IN HERTZ
(FREQ) 60.0 FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 120.0 AC AT ALTITUDE FIRST VOLTAGE
INSIDE DIAMETER
(AARX) 22.0 MILLIMETERS NOMINAL SINGLE CONNECTION
CONTACT LOAD CURRENT RATING
(CTHF) 36.0 AMPERES MOTOR LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING
(CTHF) 36.0 AMPERES MOTOR LOAD SECOND VOLTAGE
END ITEM IDENTIFICATION
(AGAV) 4120-01-671-6270
CONTACT ACTION STIMULUS
(CQGB) DECREASE
CONTACT ADJUSTABILITY
(CTYC) ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING
(CTHF) UNABLE TO DECODE
CONTACT STIMULUS RATING
(CTYX) 101.0 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 145.0 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) UNABLE TO DECODE
FREQUENCY IN HERTZ
(FREQ) UNABLE TO DECODE
INSIDE DIAMETER
(AARX) UNABLE TO DECODE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) P100 SERIES ENCAPSULATED PRESSURE CONTROLS
MEDIA FOR WHICH DESIGNED
(MEDA) GAS, LIQUEFIED
MOUNTING METHOD
(AXGY) INLET CONNECTION
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
OPERATING TEMP RATING
(AWTN) -20.0 FAHRENHEIT MINIMUM AND 150.0 FAHRENHEIT MAXIMUM
OVERALL DIAMETER
(ADAV) 0.0875 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 62.0 MILLIMETERS NOMINAL
PRESSURE SWITCH TYPE
(AJZC) DIFFERENTIAL
PRESSURE CONNECTOR TYPE
(CTZL) UNABLE TO DECODE
SENSING ELEMENT BURST PRESSURE
(CSCC) 3500.0 POUNDS PER SQUARE INCH
STYLE DESIGNATOR
(STYL) CYLINDRICAL
TERMINAL TYPE
(CSCF) WIRE LEAD
FREQUENCY IN HERTZ
(FREQ) 60.0 SECOND VOLTAGE
OPERATING TEMP RATING
(AWTN) -20.0 DEG FAHRENHEIT MINIMUM AND 150.0 DEG FAHRENHEIT MAXIMUM
PRESSURE CONNECTOR TYPE
(CTZL) FLARE, THREADED INTERNAL SINGLE CONNECTION
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 240.0 AC AT ALTITUDE SECOND VOLTAGE

Manufacturer Part Numbers