RELAY,ELECTROMAGNETIC

Federal Supply Classification
FSC 5945 - Relays and Solenoids
National Item Identification Number
NIIN 001109442
Codification Country
United States
Item Name Code
INC 32512
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 3 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5945-00-110-9442
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5945-00-110-9442


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5945-00-110-9442

National Stock Number (NSN) 5945-00-110-9442, or NIIN 001109442, (relay,electromagnetic) was assigned August 21, 1968 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 5 suppliers. Today, 5 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 23, 2008, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32512. [A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES:CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5945001109442 does not contain precious metals.

This NSN is associated to Schedule B 8536490075: relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335314: relay and industrial control manufacturing.

This information was last updated on .


Technical Characteristics

MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) UNABLE TO DECODE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 15.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
DUTY TYPE
(APNP) CONTINUOUS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE
(CSQJ) 1.688 INCHES NOMINAL SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 0.500 INCHES NOMINAL FIRST MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 1.062 INCHES NOMINAL SECOND MOUNTING FACILITY
COIL QUANTITY
(APCN) 1
ENVIRONMENTAL PROTECTION
(ADZC) HERMETIC
FREQUENCY IN HERTZ
(AJSS) 400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
(CTDL) 15.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS
(CWAB) 115.0 AC AND 28.0 DC
OVERALL HEIGHT
(ABKW) 2.250 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 2.180 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 1.530 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 1 UNTHREADED HOLE SECOND MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 1 UNTHREADED STUD FIRST MOUNTING FACILITY
MOUNTING FACILITY PATTERN
(CQYJ) IN-LINE FIRST MOUNTING FACILITY
MOUNTING FACILITY PATTERN
(CQYJ) TRIANGLE SECOND MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE
(CRPQ) 100.0 MILLIAMPERES AC SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP
(CSXF) 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
WINDING QUANTITY
(AKDX) 1
TERMINAL TYPE AND QUANTITY
(TTQY) 13 PIN CONTACTS
TERMINAL TYPE AND QUANTITY
(TTQY) 2 PIN ENERGIZING ELEMENT
TIME DELAY
(CRXH) 0.03 SECONDS NOMINAL FIXED OPERATE TIME
TIME DELAY
(CRXH) 0.05 SECONDS NOMINAL FIXED RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER
(AEBV) 0.156 INCHES NOMINAL SECOND MOUNTING FACILITY

Manufacturer Part Numbers


Related Inventory

9524-6507
5945001109442
Condition NS
RELAY
Readily Available
11106.045.02
Condition FN
HALF SHAFT
Readily Available


 