ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-00-518-1138, 5950005181138
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 005181138
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-518-1138
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-518-1138


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-518-1138

National Stock Number (NSN) 5950-00-518-1138, or NIIN 005181138, (transformer,power) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950005181138 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

BODY HEIGHT
(ADAU) 4.625 INCHES NOMINAL
BODY LENGTH
(ADAQ) 3.000 INCHES NOMINAL
BODY WIDTH
(ADAT) 2.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) THREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
THREAD QUANTITY PER INCH
(CMLP) 32 SINGLE GROUP
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 530.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY530.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY
(TTQY) 8 TAB, SOLDER LUG
UNABLE TO DECODE
(AAJF) UNABLE TO DECODE
UNABLE TO DECODE
(AAJD) UNABLE TO DECODE

Manufacturer Part Numbers

165021

RNCC
5
RNVC
9
S2382

RNCC
3
RNVC
2
S2382

RNCC
5
RNVC
9
TF1A03HA

RNCC
C
RNVC
1

Related Inventory

S-23829

Condition NE
Seal and Ship R
Readily Available
S-23825

Condition NE
Biohazard Label
Readily Available
S-23826

Condition NE
3M 600 Concrete
Readily Available
S-23824

Condition NE
Biohazard Label
Readily Available
S-23823

Condition NE
3M 2420 No Resi
Readily Available
S-23822

Condition NE
Swiffer WetJe
Readily Available
S-2382

Condition NE
5 x 9" 2 Mil In
Readily Available
1650162-3
Condition FN
701-65-02157=CO
Readily Available
1650218
3020010290198
Condition NS
FAN GUARD
Readily Available
7671C5/16X18X31/4
5306-01-416-5021
Condition NE
HEX BOLT
Readily Available
3616502-1
Condition NE
TUBE
Readily Available
099165-021
Condition FN
INSERT-BUMPER
Readily Available
S2382-6406R34-043
Condition FN
ADAPTOR
Readily Available
S-238-2
Cluster Indicat
Request


 
Top