ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-00-660-7922, 5950006607922
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 006607922
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-660-7922
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-660-7922


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-660-7922

National Stock Number (NSN) 5950-00-660-7922, or NIIN 006607922, (transformer,power) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950006607922 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) UNABLE TO DECODE
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING OPERATING VOLTAGE
(CWJS) 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
MOUNTING METHOD
(AXGY) THREADED STUD SINGLE GROUP
FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) 5.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE
(CWJS) UNABLE TO DECODE
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) UNABLE TO DECODE
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 22.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT
(CRBZ) UNABLE TO DECODE
WINDING SHIELDING METHOD
(ACZX) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BODY HEIGHT
(ADAU) 4.500 INCHES NOMINAL
BODY LENGTH
(ADAQ) 6.032 INCHES NOMINAL
BODY WIDTH
(ADAT) 4.500 INCHES NOMINAL
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SPECIAL FEATURES
(FEAT) CASE METAL MATERIAL
TERMINAL TYPE AND QUANTITY
(TTQY) 4 STANDOFF, THREADED STUD AND 1 TAB, SOLDER LUG

Manufacturer Part Numbers


Related Inventory

206-062-677-001
Condition FN
TUBE ASSY
Readily Available
12-06010
49-16-2677
Condition NE
Milwaukee Exact
Readily Available
VV11962677210R

Condition NE
Case Constructi
Readily Available
119626-77450

Condition NE
Case Constructi
Readily Available
G0462677
SP15P1
Condition NE
Sprinkler Pump,
Readily Available
G103626777
3360-14M-50
Condition NE
Bestorq Timing
Readily Available
6PRV11-1PF
196-26770-034
Condition NE
Choose Thermo S
Readily Available
6PRV11-1PT
196-26771-081
Condition NE
Choose Thermo S
Readily Available
6PRV11-TR1F
196-26772-034
Condition NE
Choose Thermo S
Readily Available
6PRV11-TR1T
196-26773-081
Condition NE
Choose Thermo S
Readily Available
6PSC9ST1F
196-26774-034
Condition NE
Use Thermo Scie
Readily Available
6PSC9ST1RF
196-26775-034
Condition NE
Use Thermo Scie
Readily Available
6PSC9ST1RT
196-26776-081
Condition NE
Use Thermo Scie
Readily Available
6PSC9ST1T
196-26777-081
Condition NE
Use Thermo Scie
Readily Available
6PSC9STB1F
196-26778-034
Condition NE
Use Thermo Scie
Readily Available
6PSC9STB1T
196-26779-081
Condition NE
Use Thermo Scie
Readily Available
MA100C-000115V1
446-26773-E1
Condition NE
Moisture analyz
Readily Available
G705362677
AK34x5/8
Condition NE
Finished Bore 1
Readily Available
G6267721
SFT8824OR
Condition NE
Drill Bushing,
Readily Available
12G940
5362677
Condition NE
Spiral Point Ta
Readily Available
31AE15
49-16-2677
Condition NE
Knockout Punch:
Readily Available
S626775-250MG
Condition NE
(3-METHYLBENZYL
Readily Available
021200-62677

Condition NE
3M Scotchmate S
Readily Available
616026-62677

Condition NE
Dynabrade 62677
Readily Available
662820-62677

Condition NE
Brady PTLTB-498
Readily Available
62677372
5330993279557
Condition NS
GASKET
Readily Available
10626770-08-04
Readily Available
10626770-12-06
Readily Available
10626770-14-04
Readily Available
10626770-14-08
Readily Available
10626770-20-05
Readily Available
10626770-20-10
Readily Available
10626770-22-10
Readily Available
10626770-24-12
Readily Available
2520123262677
0042501904
PRESSURE PLATE
Readily Available
2520123262677
0052501804
PRESSURE PLATE
Readily Available
4062677-101
Condition NE
CCA
Readily Available
D844-1032-71G
5330012626773
Condition NS
GASKET
Readily Available
D844-1032-69G
5330012626771
Condition NS
GASKET
Readily Available
BML62677
2510-01-179-8954
Request
BML24325
2510-01-346-2677
Request


 
Top