NSN 5950-00-804-6405, 5950008046405
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 008046405
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-804-6405
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-804-6405


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-804-6405

National Stock Number (NSN) 5950-00-804-6405, or NIIN 008046405, (transformer,power) was assigned January 1, 1962 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 3 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jan 01, 2013, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950008046405 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

MOUNTING METHOD
(AXGY) BRACKET SINGLE GROUP AND SLOT SINGLE GROUP
WINDING TAP LOCATION (NON-CORE)
(CQLC) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
UNABLE TO DECODE
(CQLC) UNABLE TO DECODE
WINDING POWER RATING
(CRMJ) 1.16 K1LOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE
(CWJS) 24.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
WINDING OPERATING VOLTAGE
(CWJS) 110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING
(CRMJ) 1.16 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 24.70 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
BODY HEIGHT
(ADAU) 6.031 INCHES NOMINAL
BODY LENGTH
(ADAQ) 7.062 INCHES NOMINAL
BODY WIDTH
(ADAT) 6.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) UNABLE TO DECODE
FREQUENCY RATING
(ACZB) UNABLE TO DECODE
INCLOSURE TYPE
(AKNA) PARTIALLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
MAXIMUM OPERATING TEMP
(AEHZ) 125.0 CELSIUS
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY
(TTQY) 4 WIRE LEAD AND 2 TAB, SOLDER LUG
WINDING OPERATING CURRENT
(CRBZ) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) UNABLE TO DECODE
WINDING POWER RATING
(CRMJ) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 5.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM OPERATING TEMP
(AEHZ) 125.0 DEG CELSIUS
MOUNTING METHOD
(AXGY) BRACKET AND SLOT SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 46.7 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY

Manufacturer Part Numbers

EN39

RNCC
C
RNVC
1
EN391

ISC
6
RNCC
C
RNVC
1
778161

RNCC
5
RNVC
2
EN391

RNCC
3
RNVC
9
EN39

RNCC
5
RNVC
9

Related Inventory

1J778-16-16

Condition NE
Parkrimp Perman
Readily Available
11778-16-16

Condition NE
Parkrimp Perman
Readily Available
07-15661
77816-1
Condition NE
77816-1 LYCOMIN
Readily Available
778161
SA778161
Condition NE
Sanitaire OEM #
Readily Available
G703164440
EN3-902-06-T5
Condition NE
Nylon Lifting S
Readily Available
30EN39
A20T-DWLNL3
Condition NE
Indexable Borin
Readily Available
45EN39
C86230
Condition NE
Spiral Point Ta
Readily Available
54EN39
4026
Condition NE
Double-Sided Fo
Readily Available
49EN39
GSQ2140W
Condition NE
Pail: 4 gal, Op
Readily Available
21EN39
CR6.30.10
Condition NE
Category Cable:
Readily Available
24EN39
HS120089
Condition NE
Tube Rack: 4 1/
Readily Available
2EN39
9001KR8P1G
Condition NE
Mushroom Head P
Readily Available
29EN39
STL-116-12402
Condition NE
Stencil: Forkli
Readily Available
36EN39
300-CO
Condition NE
Labor Law Poste
Readily Available
301EN391U020B2
Radialytic Rabr
Readily Available
2877816-1
3120010135959
Condition NS
BUSHING
Readily Available


 
Top