REACTOR-TRANSFORMER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 008675566
Codification Country
United States
Item Name Code
INC 02918
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-867-5566
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-867-5566


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-867-5566

National Stock Number (NSN) 5950-00-867-5566, or NIIN 008675566, (reactor-transformer) was assigned January 1, 1960 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 5 manufacturer part numbers associated with this NSN. 3 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 21, 2008, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 02918. [A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950008675566 contains an unknown precious metal.

This NSN is associated to Schedule B 8504500000: inductors, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334416: capacitor, resistor, coil, transformer, and other inductor manufacturing.

This information was last updated on .


Technical Characteristics

INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) THREE PHASE TO SIX PHASE 2ND COMPONENT
THREAD QUANTITY PER INCH
(CMLP) 32 SINGLE GROUP
INDUCTANCE RATING
(ACYV) 500.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING
(ACZB) 400.0 HERTZ NOMINAL ALL COMPONENTS
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS
(CRGS) UNABLE TO DECODE
FREQUENCY RATING
(ACZB) UNABLE TO DECODE
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INDUCTANCE RATING
(ACYV) UNABLE TO DECODE
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
MOUNTING HOLE DIAMETER
(ABTB) UNABLE TO DECODE
NOMINAL THREAD SIZE
(CQJX) UNABLE TO DECODE
OVERALL HEIGHT
(ABKW) 2.250 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 7.375 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 3.500 INCHES NOMINAL
RATING METHOD
(BKPL) UNABLE TO DECODE
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SPECIAL FEATURES
(FEAT) OUTPUT OF PHASE CONVERSION TRANSFORMER IS 6 PHASE STAR WINDING
TERMINAL TYPE AND QUANTITY
(TTQY) 14 STANDOFF, SOLDER LUG
THREAD QUANTITY PER INCH
(CMLP) UNABLE TO DECODE
THREAD SERIES DESIGNATOR
(THSD) UNABLE TO DECODE
WINDING OPERATING CURRENT
(CRBZ) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) UNABLE TO DECODE
MOUNTING METHOD
(AXGY) THREADED STUD ALL GROUPINGS OR UNTHREADED HOLE ALL GROUPINGS
MOUNTING METHOD
(AXGY) THREADED STUD OR UNTHREADED HOLE ALL GROUPINGS
NOMINAL THREAD SIZE
(CQJX) 0.190 INCHES 1ST GROUP
MOUNTING HOLE DIAMETER
(ABTB) 0.219 INCHES NOMINAL 2ND GROUP
RATING METHOD
(BKPL) ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY
RATING METHOD
(BKPL) ELECTRICAL SINGLE COMPONENT SINGLE WINDING
RATING METHOD
(BKPL) ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT
(CRBZ) 7.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
THREAD SERIES DESIGNATOR
(THSD) UNF 1ST GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 4 2ND GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 6 1ST GROUP
WINDING OPERATING VOLTAGE
(CWJS) 12.80 AC VOLTS MINIMUM AND 20.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
DC RESISTANCE RATING IN OHMS
(CRGS) 0.180 SINGLE COMPONENT SINGLE WINDING

Manufacturer Part Numbers

68042930

RNCC
3
RNVC
2
7900299

RNCC
5
RNVC
9
790029900

RNCC
5
RNVC
2
S4293

RNCC
5
RNVC
9
S4293A

RNCC
5
RNVC
9

Related Inventory

840779-00299

Condition NE
DBI-SALA Sinco
Readily Available
MPS4293
Condition FN
DIFF KIT
Readily Available


 
Top