ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-00-936-2685, 5950009362685
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 009362685
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-936-2685
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-936-2685


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-936-2685

National Stock Number (NSN) 5950-00-936-2685, or NIIN 009362685, (transformer,power) was assigned March 10, 1967 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950009362685 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

WINDING OPERATING VOLTAGE
(CWJS) 16.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY
(TTQY) 5 TAB, SOLDER LUG
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 1.015 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.045 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY HEIGHT
(ADAU) 1.880 INCHES MAXIMUM
INCLOSURE TYPE
(AKNA) PARTIALLY INCLOSED, DOUBLE SHELL
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES SINGLE GROUP
WINDING POWER RATING
(CRMJ) 0.025 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 78.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 0.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
BODY WIDTH
(ADAT) 1.560 INCHES MAXIMUM
WINDING OPERATING CURRENT
(CRBZ) 1.6 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
BODY LENGTH
(ADAQ) 1.560 INCHES MAXIMUM
UNABLE TO DECODE
(CQLC) UNABLE TO DECODE
UNABLE TO DECODE
(AAJF) UNABLE TO DECODE
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
MAXIMUM OPERATING TEMP
(AEHZ) 65.0 DEG CELSIUS
MOUNTING METHOD
(AXGY) THREADED HOLE SINGLE GROUP
UNABLE TO DECODE
(AAJD) UNABLE TO DECODE
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP

Manufacturer Part Numbers


Related Inventory

890341R91
2530007587569
Condition NS
PARTS KIT
Readily Available
7671CNAS1611-212
5331-00-890-3411
Condition NE
O-RING
Readily Available
114-389034-1
Condition NS
CONDITION CONTR
Readily Available
60-389034-1 OVH
Condition NS
FUEL TRANSMITTE
Readily Available
S30989-0341
BU890M341AT01
Condition FN
BACKUP RING, SO
Readily Available
2534-12
50-389034-12
Condition NE
FUEL CELL (PMA
Readily Available
50-389034-18
0-389034-17
Condition NS
FUEL CELL
Readily Available
101-389034-1
Condition NS
FLOAT SWITCH
Readily Available
2534-19
50-389034-17
Condition NE
FUEL CELL (PMA
Readily Available
2534-20
50-389034-18
Condition NE
FUEL CELL
Readily Available
50-389034-18
2534-20
Condition NS
FUEL CELL
Readily Available
2534-12
50-389034-8
Condition NE
FUEL CELL (PMA
Readily Available


 
Top