ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-032-0043, 5950010320043
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 010320043
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-032-0043
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-032-0043


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-032-0043

National Stock Number (NSN) 5950-01-032-0043, or NIIN 010320043, (transformer,power) was assigned December 5, 1976 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 01, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950010320043 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

MOUNTING SLOT WIDTH
(ABTD) UNABLE TO DECODE
BODY HEIGHT
(ADAU) INCHES MINIMUM 5.245 AND INCHES MAXIMUM 5.255
BODY LENGTH
(ADAQ) INCHES MINIMUM 4.870 AND INCHES MAXIMUM 4.880
BODY WIDTH
(ADAT) INCHES MINIMUM 4.370 AND INCHES MAXIMUM 4.380
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.625
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500
FEATURES PROVIDED
(CBBL) W/RECTIFIER
FREQUENCY RATING
(ACZB) SINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 70.0
INCLOSURE TYPE
(AKNA) OPEN
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MOUNTING FACILITY QUANTITY
(AKPV) 4
MOUNTING SLOT WIDTH
(ABTD) SINGLE GROUP INCHES NOMINAL 0.281
MOUNTING METHOD
(AXGY) SINGLE GROUP SLOT
SPECIAL FEATURES
(FEAT) 2PRIMARY WINDINGS; 8SECONDARY WINDINGS
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY
(TTQY) TAB, SOLDER LUG 22
WINDING OPERATING CURRENT
(CRBZ) SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 700.0
WINDING OPERATING CURRENT
(CRBZ) SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES DC MAXIMUM 700.0
WINDING OPERATING CURRENT
(CRBZ) SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC MAXIMUM 700.0
WINDING FUNCTION AND QUANTITY
(BPLC) SINGLE COMPONENT PRIMARY 2 AND SECONDARY 8
WINDING OPERATING CURRENT
(CRBZ) SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC MAXIMUM 700.0
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 8.00
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 35.00
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT FOURTH SECONDARY DC VOLTS NOMINAL 17.00
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT THIRD SECONDARY DC VOLTS NOMINAL 17.50
WINDING SHIELDING METHOD
(ACZX) SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) UNABLE TO DECODE
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) UNABLE TO DECODE
FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 70.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD
(ACZX) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
WINDING OPERATING CURRENT
(CRBZ) UNABLE TO DECODE
WINDING FUNCTION AND QUANTITY
(BPLC) 2 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT

Manufacturer Part Numbers


Related Inventory

10-05516
FF200K60
Condition NE
Aerospace Logic
Readily Available
71005516
HOSE
Readily Available


 