NSN 5950-01-119-2776, 5950011192776
Cancelled -> Replaced by 5950010670993

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 011192776
Codification Country
United States
Item Name Code
INC 00449
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-119-2776
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-119-2776


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-119-2776

National Stock Number (NSN) 5950-01-119-2776, or NIIN 011192776, (transformer assembly) was assigned September 20, 1981 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5950010670993.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 4 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 23, 2008, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00449. [TWO OR MORE SEPARABLE TRANSFORMER (AS MODIFIED) ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950011192776 does not contain precious metals.

This NSN is associated to Schedule B 8504900020: transformer parts. The Schedule B End Use is listed as generators, accessories. NAICS classification category 335311: power, distribution, and specialty transformer manufacturing.

This information was last updated on .


Technical Characteristics

BODY HEIGHT
(ADAU) 2.500 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 3.750 INCHES MAXIMUM
BODY WIDTH
(ADAT) 3.000 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 400.0 HERTZ NOMINAL ALL COMPONENTS
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) THREE PHASE TO THREE PHASE ALL COMPONENTS
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING HOLE DIAMETER
(ABTB) 0.188 INCHES NOMINAL SINGLE GROUP
MOUNTING METHOD
(AXGY) FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
RATING METHOD
(BKPL) ELECTRICAL ALL COMPONENTS SINGLE SECONDARY
RATING METHOD
(BKPL) ELECTRICAL ALL COMPONENTS SINGLE PRIMARY
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPE
(ACZD) WYE-WYE
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY ALL COMPONENTS AND 1 SECONDARY ALL COMPONENTS
WINDING OPERATING VOLTAGE
(CWJS) 11.80 AC VOLTS NOMINAL ALL COMPONENTS 3RD SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 10.50 AC VOLTS NOMINAL ALL COMPONENTS SINGLE PRIMARY
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD GROUNDED TO CORE ALL COMPONENTS
TERMINAL TYPE AND QUANTITY
(TTQY) 1 CONNECTOR, RECEPTACLE

Manufacturer Part Numbers


Related Inventory



 
Top