ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-130-3608, 5950011303608
TRANSFORMER ASSEMBLY

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 011303608
Codification Country
United States
Item Name Code
INC 00449
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-130-3608
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-130-3608


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-130-3608

National Stock Number (NSN) 5950-01-130-3608, or NIIN 011303608, (transformer assembly) was assigned April 21, 1982 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00449. [TWO OR MORE SEPARABLE TRANSFORMER (AS MODIFIED) ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950011303608 does not contain precious metals.

This NSN is associated to Schedule B 8504900020: transformer parts. The Schedule B End Use is listed as generators, accessories. NAICS classification category 335311: power, distribution, and specialty transformer manufacturing.

This information was last updated on .


Technical Characteristics

END ITEM IDENTIFICATION
(AGAV) MLRS
BODY HEIGHT
(ADAU) 1.800 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 2.525 INCHES MAXIMUM
BODY WIDTH
(ADAT) 1.025 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) UNABLE TO DECODE
DC RESISTANCE RATING IN OHMS
(CRGS) 0.0065 INSERT
DC RESISTANCE RATING IN OHMS
(CRGS) 0.048 FIRST WINDING
DC RESISTANCE RATING IN OHMS
(CRGS) 0.040 SINGLE SIDE INSCRIPTION BACKGROUND
DC RESISTANCE RATING IN OHMS
(CRGS) 0.040 SIXTH ROW SECOND POSITION HORIZONTAL FULL DISPLAY DIVISION A
DC RESISTANCE RATING IN OHMS
(CRGS) 0.100 INSULATION SUPPORTING
DC RESISTANCE RATING IN OHMS
(CRGS) 0.350 BACK
DC RESISTANCE RATING IN OHMS
(CRGS) 3.000 SINGLE REGISTER SINGLE TIER CASE
DC RESISTANCE RATING IN OHMS
(CRGS) 3.000 SIXTH ROW FOURTH POSITION HORIZONTAL FULL DISPLAY DIVISION A
FREQUENCY RATING
(ACZB) UNABLE TO DECODE
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
MAXIMUM OPERATING TEMP
(AEHZ) 155.0 CELSIUS
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
NOMINAL THREAD SIZE
(CQJX) UNABLE TO DECODE
OVERALL HEIGHT
(ABKW) 1.985 INCHES MAXIMUM
RATING METHOD
(BKPL) ELECTRICAL SCALE
RATING METHOD
(BKPL) ELECTRICAL FIFTH INTERVAL SINGLE SCALE
RATING METHOD
(BKPL) ELECTRICAL SINGLE SIDE INSCRIPTION BACKGROUND
RATING METHOD
(BKPL) ELECTRICAL SIXTH ROW FOURTH POSITION HORIZONTAL FULL DISPLAY DIVISION A
RATING METHOD
(BKPL) ELECTRICAL SIXTH ROW SECOND POSITION HORIZONTAL FULL DISPLAY DIVISION A
RATING METHOD
(BKPL) ELECTRICAL SINGLE REGISTER SINGLE TIER CASE
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SPECIAL FEATURES
(FEAT) ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS ON FIRST COMPONENT AND FOUR PRIMARY WINDINGS; ONE SECONDARY WINDING ON THIRD COMPONENT
TERMINAL TYPE AND QUANTITY
(TTQY) 17 PIN
THREAD SERIES DESIGNATOR
(THSD) UNABLE TO DECODE
WINDING OPERATING CURRENT
(CRBZ) 1.0 AMPERES AC MAXIMUM INSULATION SUPPORTING
WINDING OPERATING CURRENT
(CRBZ) 140.0 MILLIAMPERES AC MAXIMUM SINGLE REGISTER SINGLE TIER CASE
WINDING OPERATING CURRENT
(CRBZ) 6.0 AMPERES AC MAXIMUM INSERT
WINDING OPERATING CURRENT
(CRBZ) 3.2 AMPERES AC MAXIMUM SINGLE SIDE INSCRIPTION BACKGROUND
WINDING OPERATING CURRENT
(CRBZ) 3.2 AMPERES AC MAXIMUM SIXTH ROW SECOND POSITION HORIZONTAL FULL DISPLAY DIVISION A
WINDING OPERATING CURRENT
(CRBZ) 30.0 MILLIAMPERES AC MAXIMUM SIXTH ROW FOURTH POSITION HORIZONTAL FULL DISPLAY DIVISION A
WINDING OPERATING CURRENT
(CRBZ) 400.0 MILLIAMPERES AC MAXIMUM FIRST WINDING
WINDING OPERATING CURRENT
(CRBZ) 500.0 MILLIAMPERES AC MAXIMUM BACK
WINDING SHIELDING METHOD
(ACZX) UNABLE TO DECODE
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
DC RESISTANCE RATING IN OHMS
(CRGS) 3.000 2ND COMPONENT SINGLE SECONDARY
RATING METHOD
(BKPL) ELECTRICAL 2ND COMPONENT SINGLE PRIMARY
RATING METHOD
(BKPL) ELECTRICAL 2ND COMPONENT SINGLE SECONDARY
RATING METHOD
(BKPL) ELECTRICAL 1ST COMPONENT ALL SECONDARY
RATING METHOD
(BKPL) ELECTRICAL 1ST COMPONENT SINGLE PRIMARY
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT
DC RESISTANCE RATING IN OHMS
(CRGS) 0.0065 1ST COMPONENT 4TH SECONDARY
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 0.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 4 PRIMARY AND 1 SECONDARY 3RD COMPONENT
DC RESISTANCE RATING IN OHMS
(CRGS) 0.100 1ST COMPONENT 3RD SECONDARY
DC RESISTANCE RATING IN OHMS
(CRGS) 3.000 3RD COMPONENT SINGLE SECONDARY
MOUNTING FACILITY QUANTITY
(AKPV) 2 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
MAXIMUM OPERATING TEMP
(AEHZ) 155.0 DEG CELSIUS
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 5 SECONDARY 1ST COMPONENT
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY 1ST COMPONENT AND 5 SECONDARY 1ST COMPONENT
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES SINGLE GROUP
DC RESISTANCE RATING IN OHMS
(CRGS) 0.040 2ND COMPONENT SINGLE PRIMARY
MOUNTING METHOD
(AXGY) THREADED HOLE SINGLE GROUP
RATING METHOD
(BKPL) ELECTRICAL 3RD COMPONENT ALL PRIMARY
RATING METHOD
(BKPL) ELECTRICAL 3RD COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 1 SECONDARY 2ND COMPONENT
WINDING FUNCTION AND QUANTITY
(BPLC) 4 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
DC RESISTANCE RATING IN OHMS
(CRGS) 0.040 1ST COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS
(CRGS) 0.048 1ST COMPONENT 1ST SECONDARY
DC RESISTANCE RATING IN OHMS
(CRGS) 0.350 1ST COMPONENT 2ND SECONDARY
FREQUENCY RATING
(ACZB) 20.0 KILOHERTZ NOMINAL ALL COMPONENTS

Manufacturer Part Numbers


Related Inventory

12367384
2590013032507
Condition NS
BRACKET
Readily Available
12367384
2590-01-303-2507
Request


 
Top