ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-130-8505, 5950011308505
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 011308505
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: We have 1 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-130-8505
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-130-8505


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-130-8505

National Stock Number (NSN) 5950-01-130-8505, or NIIN 011308505, (transformer,power) was assigned April 29, 1982 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 5 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has been procured by the US Government within the last year, but shows no recent (last 90 days) procurement activity. There have been 3 contracts issued for this part number, with 3 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 2 different suppliers. The last contract numbers awarded were: SPE7M123P6210, SPE7MC15V1263, SPM7MC11V5774. The total value of the awarded contracts has been US$ 1,437.60.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 26, 2008, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950011308505 does not contain precious metals.

This information was last updated on .


Technical Characteristics

END ITEM IDENTIFICATION
(AGAV) LOGISTICS SUPPORT VESSEL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 5.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) OPEN
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT
(ABKW) 4.312 INCHES MAXIMUM
OVERALL LENGTH
(ABHP) 7.687 INCHES MAXIMUM
OVERALL WIDTH
(ABMK) 4.750 INCHES MAXIMUM
MAXIMUM TRANSFORMER POWER RATING
(ACZF) 0.750 KILOVOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING HOLE DIAMETER
(ABTB) 0.250 INCHES NOMINAL SINGLE GROUP
MOUNTING METHOD
(AXGY) BRACKET AND UNTHREADED HOLE SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
TERMINAL TYPE AND QUANTITY
(TTQY) 6 FERRULE CLIP
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
MOUNTING METHOD
(AXGY) BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT

Manufacturer Part Numbers


Related Inventory



 
Top