NSN 5950-01-142-9591, 5950011429591
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 011429591
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-142-9591
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-142-9591


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-142-9591

National Stock Number (NSN) 5950-01-142-9591, or NIIN 011429591, (transformer,power) was assigned November 23, 1982 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950011429591 does not contain precious metals.

This NSN is associated to Schedule B 8504314035: transformers, having a power handling capacity less than 40 va, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334416: capacitor, resistor, coil, transformer, and other inductor manufacturing.

This information was last updated on .


Technical Characteristics

FREQUENCY RATING
(ACZB) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
WINDING SHIELDING METHOD
(ACZX) UNABLE TO DECODE
WINDING OPERATING VOLTAGE
(CWJS) UNABLE TO DECODE
WINDING OPERATING CURRENT
(CRBZ) UNABLE TO DECODE
NOMINAL THREAD SIZE
(CQJX) UNABLE TO DECODE
MOUNTING METHOD
(AXGY) THREADED HOLE SINGLE GROUP
MAXIMUM OPERATING TEMP
(AEHZ) 130.0 DEG CELSIUS
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
FREQUENCY RATING
(ACZB) SINGLE COMPONENT HERTZ NOMINAL 400.0
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION
(ABFE) VIBRATION RESISTANT
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MAXIMUM TRANSFORMER POWER RATING
(ACZF) SINGLE COMPONENT VOLT-AMPERE 6.0
MAXIMUM OPERATING TEMP
(AEHZ) CELSIUS 130.0
MOUNTING FACILITY QUANTITY
(AKPV) 1
MOUNTING METHOD
(AXGY) SINGLE GROUP THREADED HOLE(S)
NOMINAL THREAD SIZE
(CQJX) SINGLE GROUP INCHES 0.138
OVERALL HEIGHT
(ABKW) INCHES MAXIMUM 1.280
OVERALL LENGTH
(ABHP) INCHES MAXIMUM 1.090
OVERALL WIDTH
(ABMK) INCHES MAXIMUM 1.090
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY
(TTQY) PIN 6
TEST DATA DOCUMENT
(TEST) SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-27
THREAD SERIES DESIGNATOR
(THSD) SINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
WINDING FUNCTION AND QUANTITY
(BPLC) SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
WINDING OPERATING CURRENT
(CRBZ) SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 1.0
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING SHIELDING METHOD
(ACZX) SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
WINDING OPERATING VOLTAGE
(CWJS) SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 6.00
SPECIFICATION/STANDARD DATA
(ZZZK) GOVERNMENT SPECIFICATION 81349--IL-T-27 TO 42
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) UNABLE TO DECODE
MAXIMUM TRANSFORMER POWER RATING
(ACZF) UNABLE TO DECODE
THREAD SERIES DESIGNATOR
(THSD) UNABLE TO DECODE
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP