ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-153-8267, 5950011538267
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 011538267
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-153-8267
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-153-8267


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-153-8267

National Stock Number (NSN) 5950-01-153-8267, or NIIN 011538267, (transformer,power) was assigned May 17, 1983 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 5 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 5 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 4 suppliers are deemed design controlled or valid supply parts.

This part number has been procured by the US Government within the last year, but shows no recent (last 90 days) procurement activity. There have been 9 contracts issued for this part number, with 9 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 3 different suppliers. The last contract numbers awarded were: SPE7M524V3694, SPE7M523V3025, SPE7M121V0975, SPE7M517V0536, SPE7M515V4690. The total value of the awarded contracts has been US$ 37,689.12.

This NSN is fairly common among different weapons systems, belonging to 19 different platforms.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 23, 2015, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950011538267 does not contain precious metals.

This information was last updated on .


Technical Characteristics

WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
BODY HEIGHT
(ADAU) 4.375 INCHES MINIMUM AND 4.500 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 2.565 INCHES MINIMUM AND 2.690 INCHES MAXIMUM
BODY WIDTH
(ADAT) 2.125 INCHES MINIMUM AND 2.250 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 1.620 INCHES MINIMUM AND 1.630 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 48.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP
(AEHZ) 155.0 DEG CELSIUS
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) THREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE
(CQJX) 0.190 INCHES SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
THREAD SERIES DESIGNATOR
(THSD) UNF SINGLE GROUP
WINDING OPERATING CURRENT
(CRBZ) 1.0 AMPERES DC MINIMUM AND 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 750.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 50.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 103.50 AC VOLTS NOMINAL AND 109.25 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.75 AC VOLTS NOMINAL AND 126.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 110.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 27.00 DC VOLTS MINIMUM AND 32.50 DC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING
(CRMJ) 5.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING
(CRMJ) 65.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING POWER RATING
(CRMJ) 4.7 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY
(TTQY) 12 TURRET
FREQUENCY RATING
(ACZB) 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT

Manufacturer Part Numbers

25P228411

ISC
5
RNCC
3
RNVC
2
25P228411

RNCC
5
RNVC
1
25P22841101

RNCC
3
RNVC
2
BTC11968

RNCC
5
RNVC
2
PEI10858

RNCC
5
RNVC
2
C18767

RNCC
5
RNVC
2

Related Inventory



 
Top