ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-216-3639, 5950012163639
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 012163639
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-216-3639
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-216-3639


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-216-3639

National Stock Number (NSN) 5950-01-216-3639, or NIIN 012163639, (transformer,power) was assigned September 9, 1985 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950012163639 does not contain precious metals.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(AAJF) UNABLE TO DECODE
THREAD CLASS (NON-CORE)
(AAJD) UNABLE TO DECODE
MAXIMUM OPERATING TEMP
(AEHZ) 220.0 DEG CELSIUS
UNABLE TO DECODE
(AAJD) UNABLE TO DECODE
UNABLE TO DECODE
(CBME) UNABLE TO DECODE
THREAD DIRECTION (NON-CORE)
(AAJF) UNABLE TO DECODE
CUBIC MEASURE (NON-CORE)
(CBME) 2615.4 CUBIC INCHES
BODY HEIGHT
(ADAU) 14.000 INCHES NOMINAL
BODY LENGTH
(ADAQ) 15.250 INCHES NOMINAL
BODY WIDTH
(ADAT) 12.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 13.750 INCHES NOMINAL 3RD MOUNTING FACILITY 3RD CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 8.000 INCHES NOMINAL 3RD MOUNTING FACILITY 3RD CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS
(AEJN) 10.000 INCHES NOMINAL 1ST MOUNTING FACILITY 1ST CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS
(AEJN) 10.000 INCHES NOMINAL 2ND MOUNTING FACILITY 2ND CENTER GROUP
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP
(AEHZ) 220.0 CELSIUS
MOUNTING FACILITY QUANTITY
(AKPV) 2 1ST GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 2 2ND GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 4 3RD GROUP
MOUNTING HOLE DIAMETER
(ABTB) 0.100 INCHES NOMINAL 2ND GROUP
MOUNTING SLOT WIDTH
(ABTD) 0.568 INCHES NOMINAL 1ST GROUP
MOUNTING METHOD
(AXGY) SLOT 1ST GROUP
MOUNTING METHOD
(AXGY) THREADED HOLE 3RD GROUP
MOUNTING METHOD
(AXGY) UNTHREADED HOLE 2ND GROUP
NOMINAL THREAD SIZE
(CQJX) 0.500 INCHES 3RD GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 20.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 187.20 AC VOLTS MINIMUM AND 228.80 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 863.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING
(CRMJ) 17.26 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY
(TTQY) 4 WIRE LEAD
THREAD SERIES DESIGNATOR
(THSD) UNC 3RD GROUP

Manufacturer Part Numbers

122707

RNCC
5
RNVC
2
4254101

RNCC
3
RNVC
2
C193162

ISC
5
RNCC
C
RNVC
1
C193162

RNCC
5
RNVC
9
PEI6194

RNCC
5
RNVC
2

Related Inventory

56122707
AD56122707
Condition NE
Advance OEM Par
Readily Available
4122707
TKD4122707
Condition NE
Taski OEM Part
Readily Available
G1227073
ZB4BC2
Condition NE
Push Button ope
Readily Available
49TY76
141227070
Condition NE
Class X No-Go P
Readily Available
1227075
TN1227075
Condition NE
Tennant OEM Par
Readily Available
1227074
TN1227074
Condition NE
Tennant OEM Par
Readily Available
754473-71664

Condition NE
Brady B-120 Fib
Readily Available
1-227079-6
Condition FN
COMM BNC PLUG
Readily Available
042541-01
Readily Available
624254-1014DN3
5306013661112
Condition NS
BOLT, MACHINE
Readily Available
12270730
4710010764334
Condition NS
TUBE
Readily Available
AN122707
Readily Available
12270740
4710010757906
Condition NS
TUBE ASSY
Readily Available
624254-1016DN3
Readily Available
4P94254-101A
3120000847071
Condition NS
BEARING
Readily Available
624254-1016DN3
5306013694801
Condition NS
BOLT
Readily Available
1634254-101
Condition FN
Desc: GASKET; M
Readily Available
M200SERIES1X1-8
9330009122707
Condition NS
PLASTIC STRIP
Readily Available
AN122707
5315002412919
Condition NS
PIN
Readily Available


 
Top