NSN 5950-01-224-6187, 5950012246187
TRANSFORMER,POWER

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 012246187
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: We have 2 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-224-6187
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-224-6187


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-224-6187

National Stock Number (NSN) 5950-01-224-6187, or NIIN 012246187, (transformer,power) was assigned January 17, 1986 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over a year. There have been 5 contracts issued for this part number, with 5 awards given. The US Government has only awarded those contracts to one supplier. The last contract numbers awarded were: SPE4A519P7873, SPE4A413VD358, SPE4A513M3680, SPE4A513M3348, SPM4A512ME528. The total value of the awarded contracts has been US$ 62,456.66.

This NSN is somewhat common among different platforms, belonging to 3 different weapons systems.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Mar 16, 2012, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950012246187 does not contain precious metals.

This NSN is associated to Schedule B 8504314035: transformers, having a power handling capacity less than 40 va, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334416: capacitor, resistor, coil, transformer, and other inductor manufacturing.

This information was last updated on .


Technical Characteristics

BODY LENGTH
(ADAQ) 0.500 INCHES MAXIMUM
BODY OUTSIDE DIAMETER
(ADAR) 2.000 INCHES MAXIMUM
FEATURES PROVIDED
(CBBL) COLOR CODED LEAD
FREQUENCY RATING
(ACZB) 400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP
(AEHZ) 155.0 DEG CELSIUS
MAXIMUM TRANSFORMER POWER RATING
(ACZF) 1.0 WATTS SINGLE COMPONENT
MOUNTING METHOD
(AXGY) TERMINAL SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 10.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT
(CRBZ) 110.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 110.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 520.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 23.40 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING
(CRMJ) 1.2 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING
(CRMJ) 12.2 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING
(CRMJ) 2.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING
(CRMJ) 2.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 8.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
TERMINAL TYPE AND QUANTITY
(TTQY) 13 WIRE LEAD
UNABLE TO DECODE
(KZTS) UNABLE TO DECODE
UNABLE TO DECODE
(CQLC) UNABLE TO DECODE