ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-01-288-8929, 5950012888929
Cancelled -> Replaced by 5950012848902

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 012888929
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-288-8929
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-288-8929


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-288-8929

National Stock Number (NSN) 5950-01-288-8929, or NIIN 012888929, (transformer,power) was assigned November 17, 1988 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5950012848902.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950012888929 does not contain precious metals.

This information was last updated on .


Technical Characteristics

WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
MOUNTING FACILITY QUANTITY
(AKPV) 2 SINGLE GROUP
MOUNTING METHOD
(AXGY) UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 460.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 460.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY

Manufacturer Part Numbers


Related Inventory

08-00617
16510
Condition NE
Thermo-Tec Heat
Readily Available
G800617740
S71004
Condition NE
½" PEX (F1960)
Readily Available
G209919612
UJ-2000 BOOT
Condition NE
Boot Kit
Readily Available
60EU81
7800617
Condition NE
Indexable Profi
Readily Available
53ZY69
1800617
Condition NE
Band Saw Blade:
Readily Available
662820-99196

Condition NE
Brady Permaslee
Readily Available
870-50567
5420991961416
Condition NS
BRACKET
Readily Available
4537800-617
2815011665625
Condition NS
PRECHAMBER
Readily Available
20800-617
Condition FN
Desc: INDICATOR
Readily Available
800617
Condition FN
VALVE DASH
Readily Available


 
Top