COIL ASSEMBLY,RADIO FREQUENCY

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 013049107
Codification Country
United States
Item Name Code
INC 00345
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-304-9107
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-304-9107


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-304-9107

National Stock Number (NSN) 5950-01-304-9107, or NIIN 013049107, (coil assembly,radio frequency) was assigned July 28, 1989 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 2 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00345. [TWO OR MORE COILS ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER. EXCLUDES:ITEMS INDUCTIVELY COUPLED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950013049107 does not contain precious metals.

This NSN is associated to Schedule B 8504900080: static converter & inductor parts, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334419: other electronic component manufacturing.

This information was last updated on .


Technical Characteristics

COIL FORM TYPE
(ACZP) UNABLE TO DECODE
CORE CONSTRUCTION
(ACZR) UNABLE TO DECODE
DC RESISTANCE RATING IN OHMS
(CRGS) 0.960 LOWEST RESISTANCE VALUE
DC RESISTANCE RATING IN OHMS
(CRGS) 66.000 SIXTH ROW SIXTH POSITION VERTICAL FULL DISPLAY DIVISION A
INDUCTANCE RATING
(ACYV) 22.00 MICROHENRIES NOMINAL LOWEST RESISTANCE VALUE
INDUCTANCE RATING
(ACYV) 5.10 MILLIHENRIES NOMINAL SIXTH ROW SIXTH POSITION VERTICAL FULL DISPLAY DIVISION A
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
QUALITY FACTOR
(CRHJ) 45 MINIMUM LOWEST RESISTANCE VALUE
QUALITY FACTOR
(CRHJ) 70 MINIMUM SIXTH ROW SIXTH POSITION VERTICAL FULL DISPLAY DIVISION A
RATING METHOD
(BKPL) UNABLE TO DECODE
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY
(TTQY) 4 WIRE LEAD
SPECIAL FEATURES
(FEAT) TERMINAL 14 INTERNALLY CONNECTED TO TERMINAL 15
WINDING OPERATING CURRENT
(CRBZ) 290.0 MILLIAMPERES DC NOMINAL LOWEST RESISTANCE VALUE
WINDING OPERATING CURRENT
(CRBZ) 48.0 MILLIAMPERES DC NOMINAL SIXTH ROW SIXTH POSITION VERTICAL FULL DISPLAY DIVISION A
WINDING QUANTITY
(AKDX) UNABLE TO DECODE
RATING METHOD
(BKPL) ELECTRICAL ALL COMPONENTS SINGLE WINDING
DC RESISTANCE RATING IN OHMS
(CRGS) 0.960 1ST COMPONENT SINGLE WINDING
QUALITY FACTOR
(CRHJ) 70 MINIMUM 2ND COMPONENT SINGLE WINDING
MOUNTING METHOD
(AXGY) TERMINAL SINGLE GROUP
DC RESISTANCE RATING IN OHMS
(CRGS) 66.000 2ND COMPONENT SINGLE WINDING
CORE CONSTRUCTION
(ACZR) S0LID 2ND COMPONENT
COIL FORM TYPE
(ACZP) SOLID ALL COMPONENTS
QUALITY FACTOR
(CRHJ) 45 MINIMUM 1ST COMPONENT SINGLE WINDING
CORE CONSTRUCTION
(ACZR) POWDERED 1ST COMPONENT
WINDING QUANTITY
(AKDX) 1 ALL COMPONENTS