NSN 5950-01-564-5627, 5950015645627
REACTOR

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 015645627
Codification Country
United States
Item Name Code
INC 00724
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-01-564-5627
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-01-564-5627


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-01-564-5627

National Stock Number (NSN) 5950-01-564-5627, or NIIN 015645627, (reactor) was assigned June 19, 2008 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Aug 19, 2017, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The design of this part is unstable. Engineering, manufacturing, or performance characteristics indicate that the required design objectives have not been achieved. Major changes are contemplated because the part has a low process yield or has demonstrated marginal performance during tests or service use. These changes will render the present part obsolete and unusable in its present configuration. Limited acquisition from the present source is anticipated pending configuration changes. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00724. [A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES:SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950015645627 does not contain precious metals.

This NSN is associated to Schedule B 8504900020: transformer parts. The Schedule B End Use is listed as generators, accessories. NAICS classification category 335311: power, distribution, and specialty transformer manufacturing.

This information was last updated on .


Technical Characteristics

RATING METHOD
(BKPL) UNABLE TO DECODE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS
(AEJN) UNABLE TO DECODE
WINDING QUANTITY
(AKDX) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY
(AKPV) UNABLE TO DECODE
END ITEM IDENTIFICATION
(AGAV) PANEL/CABINET
DISTANCE BETWEEN MOUNTING FACILITY CENTERS
(AEJN) 3.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS
INCLOSURE TYPE
(AKNA) OPEN
INDUCTANCE RATING
(ACYV) 2.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
OVERALL LENGTH
(ABHP) 7.250 INCHES MAXIMUM
OVERALL WIDTH
(ABMK) 6.000 INCHES MAXIMUM
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) 3-PHASE REACTOR ASSEMBLY
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) SLOT SINGLE GROUP
MOUNTING SLOT WIDTH
(ABTD) 0.390 INCHES NOMINAL SINGLE GROUP
OVERALL HEIGHT
(ABKW) 4.300 INCHES MAXIMUM
SPECIAL FEATURES
(FEAT) 3 PHASE REACTOR ASSY;18 POUNDS;WATT LOSS 61;CABINET-CAB-13
RATING METHOD
(BKPL) ELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY
(TTQY) 1 TERMINAL BLOCK W/SCREWS
WINDING OPERATING CURRENT
(CRBZ) 25.0 AMPERES DC MINIMUM AND 37.5 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING QUANTITY
(AKDX) 1 SINGLE COMPONENT
MOUNTING METHOD
(AXGY) UNABLE TO DECODE
INDUCTANCE RATING
(ACYV) UNABLE TO DECODE
MOUNTING SLOT WIDTH
(ABTD) UNABLE TO DECODE