NSN 5985-00-224-5429, 5985002245429
DUMMY LOAD,ELECTRICAL

Federal Supply Classification
FSC 5985 - Antennas, Waveguides, and Related Equipment
National Item Identification Number
NIIN 002245429
Codification Country
United States
Item Name Code
INC 00335
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5985-00-224-5429
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5985-00-224-5429


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5985-00-224-5429

National Stock Number (NSN) 5985-00-224-5429, or NIIN 002245429, (dummy load,electrical) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00335. [A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES:POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5985002245429 contains an unknown precious metal.

This NSN is associated to Schedule B 9030330080: other instruments and apparatus for measuring or checking power, without a recording device, nesoi. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334515: instrument manufacturing for measuring and testing electricity and electrical signals.

This information was last updated on .


Technical Characteristics

FREQUENCY RANGE RATING
(AFGQ) +2600.000 TO 3950.000 MEGAHERTZ
IMPEDANCE RATING IN OHMS
(ACYW) 50.0 NOMINAL
OVERALL DIAMETER
(ADAV) 4.875 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 30.000 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) 1 COV PROT W/RBR GSKT ATCH TO DUM LOAD BY CH 1 RBR GSKT AND 1 CS TYPE NO CY765/U
POWER RATING
(AJDB) 1.500 MEGAWATTS PEAK AND 600.000 WATTS AVERAGE
TERMINATION TYPE
(AKRZ) WAVEGUIDE FLANGE
FREQUENCY RANGE RATING
(AFGQ) +2600.000/+3950.000 MEGAHERTZ

Manufacturer Part Numbers