NSN 5985-00-284-6781, 5985002846781
LINE,RADIO FREQUENCY TRANSMISSIO

Federal Supply Classification
FSC 5985 - Antennas, Waveguides, and Related Equipment
National Item Identification Number
NIIN 002846781
Codification Country
United States
Item Name Code
INC 00884
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5985-00-284-6781
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5985-00-284-6781


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5985-00-284-6781

National Stock Number (NSN) 5985-00-284-6781, or NIIN 002846781, (line,radio frequency transmissio) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 21, 2013, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00884. [AN ITEM DESIGNED PRIMARILY FOR THE CONDUCTION OF RADIO FREQUENCY ENERGY, AND CONSISTING OF TWO OR MORE CONDUCTORS SUPPORTED IN FIXED SPATIAL RELATIONSHIP(S) ALONG THEIR OWN LENGTH. SINCE THE CHARACTERISTIC IMPEDANCE OF THE LINE IS DETERMINED BY THE SPATIAL RELATIONSHIPS OF THE CONDUCTORS, WHICH ARE SUFFICIENTLY RIGID TO MAINTAIN THESE RELATIONSHIPS BETWEEN SUPPORTS, THE CONFIGURATION OF THE ITEM IS USUALLY NOT SUSCEPTIBLE TO MECHANICAL MANIPULATION; THAT IS, IT IS NOT NORMALLY FLEXIBLE. INCLUDES A SINGLE CONDUCTOR INCLOSED IN AN OUTER CONCENTRIC CONDUCTOR (COAXIAL) OR TWO OR MORE CONDUCTORS LAID PARALLEL. ALL TYPES HAVE LOW LOSS OR SPECIAL CHARACTERISTICS AT HIGH FREQUENCIES. MAY INCLUDE FITTINGS OR TERMINATIONS. FOR ITEMS HAVING CONTINUOUS HOMOGENEOUS DIELECTRIC, SEE CABLE, RADIO FREQUENCY. SEE ALSO LINE SECTION, RADIO FREQUENCY TRANSMISSION.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5985002846781 does not contain precious metals.

This NSN is associated to Schedule B 8529109000: antenna & antenna reflectors of all kinds; parts suitable for use soley or principally w/ apparatus of heading 8525 to 8528, nesoi. The Schedule B End Use is listed as telecommunications equipment. NAICS classification category 334220: radio and television broadcasting and wireless communications equipment manufacturing.

This information was last updated on .


Technical Characteristics

III END ITEM IDENTIFICATION
(AGAV) TYPE NO. OA-422/MPS-9
UNABLE TO DECODE
(APYQ) UNABLE TO DECODE
MATERIAL
(MATL) BRASS
SURFACE TREATMENT
(SURF) PAINT
TERMINAL FITTING
(AQBD) INCLUDED
UNABLE TO DECODE
(AQBD) UNABLE TO DECODE
TERMINATION CONTROLLING AGENCY
(AQBB) JCENS
ACCOMMODATED CONDUCTOR TYPE
(AQCE) COAXIAL
CHARACTERISTIC IMPEDANCE IN OHMS
(AJDD) 52.5
CONDUCTOR QUANTITY
(AMQN) 1
END ITEM IDENTIFICATION
(AGAV) TYPE NO. OA-422/MPS-9
OUTSIDE DIAMETER
(ABHE) 0.875 INCHES NOMINAL
OVERALL LENGTH
(AAJU) 2.854 FEET
MATERIAL
(MATT) COPPER ALLOY
TUBING OUTSIDE DIAMETER
(AQRX) 0.375 INCHES NOMINAL
TUBING INSIDE DIAMETER
(AQRY) 0.312 INCHES NOMINAL
TERMINATION IDENTIFICATION
(AJDF) TYPE NO.UG-46/U AND UG-45/U
OUTER CONDUCTOR
(APZC) INCLUDED
UNABLE TO DECODE
(APZC) UNABLE TO DECODE
CONDUCTOR MATERIAL
(APYQ) BRASS
UNABLE TO DECODE
(AQBB) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory

HL414-14-18
Condition NE
HI-LOK PIN
Readily Available
101-341414-1
Condition NS
BRACKET
Readily Available
3916361
5305014141415
Condition NS
SCREW
Readily Available
SM-C-414141-2
5999008536667
Condition NS
CONTACT
Readily Available


 
Top