ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5990-00-871-9528, 5990008719528
Cancelled -> Replaced by 5990008372318

Federal Supply Classification
FSC 5990 - Synchros and Resolvers
National Item Identification Number
NIIN 008719528
Codification Country
United States
Item Name Code
INC 22966
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 1 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5990-00-871-9528
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5990-00-871-9528


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5990-00-871-9528

National Stock Number (NSN) 5990-00-871-9528, or NIIN 008719528, (resolver,electrical) was assigned January 1, 1960 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5990008372318.

There are 3 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 3 suppliers are deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has been procured by the US Government within the last year, but shows no recent (last 90 days) procurement activity. There has been one contract issued for this part number, with one award given. The US Government has only awarded those contracts to one supplier. The last contract numbers awarded were: SPE7M524P2857. The total value of the awarded contracts has been US$ 2,766.00.

This NSN is somewhat common among different platforms, belonging to 8 different weapons systems.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. The 24 month forecast from the US Government for this part number has high volatility, with an estimated forecasted value of US$ 1,680. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 22966. [AN ITEM CONSISTING OF A ROTOR AND A STATOR INDUCTIVELY COUPLED. IT USUALLY HAS TWO ROTOR WINDINGS DISPLACED FROM EACH OTHER BY 90 DEGREES AND TWO STATOR WINDINGS SIMILARLY DISPLACED. THE OUTPUT VOLTAGE(S) IS A TRIGONOMETRIC FUNCTION OF THE INPUT VOLTAGE(S) AND THE ANGULAR DISPLACEMENT OF THE ROTOR WITH RESPECT TO THE STATOR. SEE ALSO SYNCHRO (AS MODIFIED) AND GONIOMETER, ELECTRICAL. EXCLUDES:TRANSOLVER, ELECTRICAL AND POTENTIOMETER SINE/COSINE ELECTRICAL RESOLVERS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5990008719528 contains an unknown precious metal.

This NSN is associated to Schedule B 9018903000: anesthetic instruments and appliances and parts and accessories. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

ELECTRICAL ERROR ANGULAR RANGE IN MINUTES
(AJVL) -15.0/+15.0
OUTPUT VOLTAGE FUNCTIONAL ERROR RANGE IN PERCENT
(AJVK) -0.1/+0.1
ELECTRICAL ERROR ANGULAR RANGE IN MINUTES
(AJVL) -15.0 TO 15.0
ALIGNMENT HOLE BOLT CIRCLE DIAMETER
(CTCW) 0.6780 INCHES NOMINAL
ALIGNMENT HOLE DEPTH
(CRSY) 0.0930 INCHES NOMINAL
ALIGNMENT HOLE QUANTITY
(AJVW) 3
BODY MATERIAL
(AAFZ) STEEL, STAINLESS
BODY SIZE
(AJSL) 10
BODY STYLE
(AAQL) STANDARD ROUND C
FLANGE DIAMETER
(ABKK) 0.9370 INCHES NOMINAL
FLANGE THICKNESS
(ABKU) 0.0625 INCHES NOMINAL
FREQUENCY IN HERTZ
(AJSS) 400.0 NOMINAL
OUTPUT VOLTAGE FUNCTIONAL ERROR RANGE IN PERCENT
(AJVK) -0.1 TO 0.1
OVERALL LENGTH
(ABHP) 1.6710 INCHES MAXIMUM
MAXIMUM TOTAL NULL VOLTAGE OUTPUT IN MILLIVOLTS PER VOLT
(AJVH) 40.00
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 1.2810 INCHES MAXIMUM
ROTOR DC RESISTANCE IN OHMS
(AJTS) 32.00 NOMINAL
SHAFT DIAMETER
(ABWV) 0.0900 INCHES NOMINAL SINGLE SHAFT
SHAFT LENGTH
(ABXF) 0.3900 INCHES NOMINAL SINGLE SHAFT
SHAFT SLOT DEPTH
(CQZS) 0.0370 INCHES NOMINAL SINGLE SHAFT
SHAFT SLOT WIDTH
(CRHN) 0.0320 INCHES NOMINAL SINGLE SHAFT
SHAFT TYPE
(CRSJ) ROUND, SLOTTED SINGLE SHAFT
SHOULDER DIAMETER
(AAVH) 0.8123 INCHES NOMINAL
SHOULDER LENGTH
(AJWR) 0.0625 INCHES NOMINAL
PILOT DIAMETER
(AAVL) 0.5000 INCHES NOMINAL
PILOT LENGTH
(AJWQ) 0.0380 INCHES NOMINAL
PHASE SHIFT ANGLE IN DEG
(AJVF) 11.000 INPUT TO OUTPUT NOMINAL
PLUS J ZRO REACTANCE IN OHMS
(CQXQ) 119.00 NOMINAL
PLUS J ZRS REACTANCE IN OHMS
(CRKL) 14.00 NOMINAL
PLUS J ZSO REACTANCE IN OHMS
(CRGZ) 783.00 NOMINAL
UNDERCUT DIAMETER
(ABPA) 0.8400 INCHES NOMINAL
UNDERCUT WIDTH
(ABPC) 0.0620 INCHES NOMINAL
ZRO RESISTANCE IN OHMS
(AJSW) 34.00 NOMINAL
ZRS RESISTANCE IN OHMS
(AJTA) 44.00 NOMINAL
ZSO RESISTANCE IN OHMS
(AJSY) 212.00 NOMINAL
STATOR DC RESISTANCE IN OHMS
(AJTT) 166.00 NOMINAL
STATOR INPUT CURRENT RATING
(AJSP) 32.0 MILLIAMPERES NOMINAL
STATOR INPUT ELECTRICAL POWER RATING
(AJSQ) 220.0 MILLIWATTS NOMINAL
STATOR INPUT VOLTAGE RATING IN VOLTS
(AJSN) 26.0 NOMINAL
TERMINAL LOCATION
(CQTM) REAR
TERMINAL TYPE AND QUANTITY
(TTQY) 7 WIRE LEAD

Manufacturer Part Numbers


Related Inventory

75-101-242
Condition FN
#1x3/8x1/2 P-BU
Readily Available
05-14073
101-24200
Condition NE
CLEVELAND O-RIN
Readily Available
01-01242
29139
Condition NE
POLYFIX 17500 O
Readily Available
10-03939
101242-000
Condition NE
DYNON SKYVIEW G
Readily Available
101242-100
4531508
Condition NE
Epibond 215 A/B
Readily Available
89976845
5331012420711
Condition NS
PACKING
Readily Available
101242N040AA2B
Computer Grade
Readily Available
74457-11
5365010124277
Condition NE
SPACER
Readily Available
S2-4L
5331012420446
Condition NS
O-RING
Readily Available
25610-1-24-24D
Readily Available
9358424
4931012422497
Condition NS
ADAPTER
Readily Available
W199X-8
5945010124223
Condition NS
POWER RELAY
Readily Available
B715-51-18
5331012427005
Condition NS
O-RING
Readily Available
101-24200
Condition NS
ORING
Readily Available
MS28775-382
5331011012421
Condition NS
O-RING
Readily Available
MS28775-382
5330011012421
Condition NS
O-RING
Readily Available
101-242
Condition NS
O RING
Readily Available
FDC-4510-124-2-3
5340014064191
Condition NS
STRAP
Readily Available
A-A-59474
5970010124280
Condition NS
TAPE
Readily Available
071-01242-0000
Slaving Accesso
Request
071-01242-0001
Slaving Accesso
Request
071-01242-0002
Slaving Accesso
Request
071-01242-0003
Slaving Accesso
Request
071-01242-0004
Slaving Accesso
Request
071-01242-0005
Slaving Accesso
Request
071-01242-0006
Slaving Accesso
Request
071-01242-0007
Slaving Accesso
Request
071-01242-0008
Slaving Accesso
Request
071-01242-0009
Slaving Accesso
Request
071-01242-0010
Slaving Accesso
Request
071-01242-0011
Slaving Accesso
Request
071-01242-0012
Slaving Accesso
Request
071-01242-0013
Slaving Accesso
Request
071-01242-0014
Slaving Accesso
Request


 
Top